Search results

Showing 2204 results found searching:

254µm copperbond earth rods

Aplicaciones Tecnológicas, S.A. uses copperbond earth rods of a high quality which comply with even the most demanding regulations in order to achieve long-lasting earthing. All these earth rods are electrolytically coated with copper which is 254 µm thick and 99.9% pure, with a proven resistance to corrosion.

APLICEM

In high resistivity soils it is necessary to use a specific material to obtain a suitable grounding resistance.

APLIROD® dynamic electrode

Earthing systems using dynamic electrodes are based on the contribution of ions to the ground. The system consists of a copper electrode (APLIROD®) filled with a mixture of ionic compounds. The moisture condenser absorbs environmental moisture and dissip

APLIWELD®-E

Traditionally, once the conductors were inserted in the graphite mould, the welding compound and the reactive powder (usually a flammable compound) were poured into the crucible. Then a flint gun, applied manually to the starting powder at arm’s length produced a spark triggering the exothermic reaction. With APLIWELD® -E, the electronic starter is inserted on top and activated from a distance. Hence it is completely safe for the operator.

APLIWELD®-T

Traditionally, exothermic welding required the user to have multiple cartridges with different powder weights for carrying out the various connections. With APLIWELD® -T the required number of tablets are placed inside the graphite mould. Hence there is no need for multiple cartridges.

AT-004G - ATLOGGER

ATLOGGER - Recorder and analyser of lightning strikes to the protection system.

AT-009G - Self-drill screw

3.9 x 25 mm self - drill screw for fixing cable or tape clips metal sheets and sandwich panels. Includes ø18 mm neoprene washer.

AT-068N - Basic tool Set

Basic tool Set. Includes flint igniter, conductor cleaning brush, vertical mould cleaning brush, slag removal spade, cavity cleaning brush, sealer compound (0,45 kg) and safety gloves.

AT-069N - Basic tool set Apliweld-E

Basic set of accessories for Apliweld-E: cleaning brush for conductors, slag removal spade, mould brush, cavity cleaning brush, sealer compound and safety gloves.

AT-100N - Kit Apliweld-E: Ignition kit

Kit Apliweld-E: Ignition box enables controlled and remote electronic ignition in a quick and safe way. Includes: ignition unit (AT-096N), cable (AT-098N), 5 crocodile clips (AT-099N), battery charger and transporting bag.

AT-2102 - ATFREQ-50UHF

ATFREQ-UHF - Surge protector for coaxial cables. UHF connector. Frequency range - 0-3 GHz. Attenuation < 0,3dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V.

AT-2103 - ATFREQ-SAT

ATFREQ-F - Surge protector for satellite TV signal. F connector. Frequency range - 0-2 GHz. Attenuation < 0,5dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V. Includes F adaptor.

AT-2104 - ATFREQ-TV

ATFREQ-TV - Surge protector for TV signal. Frequency range - 0-1 GHz. Attenuation < 1,2dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V.

AT-2105 - ATFREQ-50BNC015

ATFREQ-50BNC 015 - Surge protector for coaxial cables. BNC connector. Frequency range - 0-1 GHz. Attenuation < 0,15dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V. Includes BNC adaptor.

AT-2106 - ATFREQ-50N

ATFREQ-50N - Surge protector for coaxial cables. N connector. Frequency range - 0-3 GHz. Attenuation < 0,15dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V.

AT-2107 - ATLAN 100 BASE-T

ATLAN 100 BASE-T - Surge protector for 100 MBits/s computer networks in a metallic enclosure. RJ45 input/output connectors. C2 Test (2kA/4kV). Up = 100V. Includes RJ45 cable, 0,5 m long.

AT-2108 - ATFREQ-400BNC015

ATFREQ-400BNC 015 - Surge protector for coaxial cables. BNC connector. Frequency range - 0-3 GHz. Attenuation < 0.15dB. Exchanged Power = 400W. Imax(8/20) = 10kA. DC Sparkover voltage = 250V. Includes BNC adaptor.

AT-2109 - ATFREQ-400UHF

ATFREQ-400UHF - Surge protector for coaxial cables. UHF connector. Frequency range - 0-3 GHz. Attenuation < 0,3dB. Exchanged Power = 400W. Imax(8/20) = 10kA. DC Sparkover voltage = 250V.

AT-2110 - ATFREQ-7/16

ATFREQ-7/16 - Surge protector for coaxial cables. 7/16' connector. Frequency range - 0,9-2,6 GHz. Attenuation < 0,3dB. Exchanged Power = 900W. Imax(8/20) = 10kA. DC Sparkover voltage = 600V.

AT-2111 - ATFREQ-400N

ATFREQ-400N - Surge protector for coaxial cables. N connector. Frequency range - 0-3 GHz. Attenuation < 0,15dB. Exchanged Power = 400W. Imax(8/20) = 10kA. DC Sparkover voltage = 250V.

AT-2115 - ATFREQ-50BNC

ATFREQ-50BNC - Surge protector for coaxial cables. BNC connector. Frequency range - 0-1 GHz. Attenuation < 0,2dB. Exchanged Power - 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V. Includes BNC adaptor.

AT-2117 - ATFREQ-50SMA

ATFREQ-50SMA - Surge protector for coaxial cables. SMA connector. Frequency range - 0-1 GHz. Attenuation < 0,2dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V.

AT-2118 - ATFREQ-400BNC

ATFREQ-400BNC - Surge protector for coaxial cables. BNC connector. Frequency range - 0-3 GHz. Attenuation < 0,2dB. Exchanged Power = 400W. Imax(8/20) = 10kA. DC Sparkover voltage = 250V. Includes BNC adaptor.

AT-2119 - ATFREQ-6G

ATFREQ-6G - Surge protector for coaxial cables. N connector. Frequency range - 0-5,8 GHz. Attenuation < 0,2dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V. (F/M).

AT-2120 - ATFREQ-75BNC

ATFREQ-75BNC - Surge protector for coaxial cables. BNC 75 Ohms connector. Frequency range - 0-1 GHz. Attenuation < 0,2dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V. Includes BNC adaptor.

AT-2121 - ATFREQ-1200

ATFREQ-1200UHF - Surge protector for coaxial cables. UHF connector. Frequency range - 0-3 GHz. Attenuation < 0,3dB. Exchanged Power = 1200W. Imax(8/20) = 10kA. DC Sparkover voltage = 250V.

AT-2123 - ATFREQ-50TNC

ATFREQ-50TNC - Surge protector for coaxial cables. TNC connector. Frequency range - 0-2,6 GHz. Attenuation < 0,5dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V.

AT-2126 - ATFREQ-6GSMA

ATFREQ-6G SMA - Surge protector for coaxial cables. SMA connector. Frequency range - 0-5,8 GHz. Attenuation < 0,2dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V.

AT-2201 - ATLAN 8/24

ATLAN 8/24 - Metal panel for up to 3 ATLAN 8 PCB modules (8, 16 or 24 connections). To be mounted on 19'' computer racks.

AT-2204 - ATLAN 1000BASE-T POE

ATLAN 1000 BASE-T POE - Surge protector for POE computer networks in a metallic enclosure. 1 GBit/s. Protects power supply (48V) and data pairs. RJ45 input/output. Up = 200V. Includes RJ45 cable, 0,5 m long.

AT-2206 - ATLAN 8

ATLAN 8 - Surge protector for computer networks. 1 GBit/s. RJ45 input/output. C2 test (2kA/4kV). Up = 100V. Includes 8 cables with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2207 - ATLAN 1000 BASE-T

ATLAN 1000 BASE-T - Surge protector for computer networks in a metallic enclosure. 1 GBit/s. RJ45 input/output. Up = 100V. Includes RJ45 cable, 0,5 m long.

AT-2208 - ATLAN 24

ATLAN 24 - Surge protector for computer networks. RJ45 input/output. 1 GBit/s. Up = 100V. C2 test (2kA/4kV). Includes 24 cables with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2209 - ATLAN 16

ATLAN 16 - Surge protector for computer networks. RJ45 input/output. 1 GBit/s. Up = 100V. C2 test (2kA/4kV). Includes 16 cables with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2210 - ATLAN 1000 BASE-T CAT6 POE

ATLAN 1000 BASE-T CAT6 POE - Individual surge protector in a metallic enclosure for POE network with category 6 cables. 1 GBit/s. RJ45 input/output. C2 Test (2kA/4KV). Up = 250V. Includes RJ45 cable, 0,5 m long.

AT-2211 - ATLAN 12 CAT6

ATLAN 12 CAT6 - Surge protector for category 6 computer networks. 1 GBit/s. RJ45 input/output connectors.UC2 test (2kA/4kV). Up = 150V. Includes 12 cables (CAT6) with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2212 - ATLAN 8 CAT6

ATLAN 8 CAT6 - Surge protector for category 6 computer networks. 1 GBit/s. RJ45 input/output connectors.UC2 test (2kA/4kV). Up = 150V. Includes 8 cables (CAT6) with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2213 - ATLAN 1000 BASE-T CAT6

ATLAN 1000 BASE-T CAT6 - Surge protector for computer networks cat6 in a metallic enclosure. 1 GBit/s. RJ45 input/output. C2 Test (2kA/4KV). Up = 100V. Includes RJ45 cable, 0,5 m long.

AT-2215 - ATLAN 8 PCB

ATLAN 8 PCB - Surge protection module for spare parts of series ATLAN 8/16/24 with 8 computer lines. 1 GBit/s. RJ45 input/output connectors. C2 test (2kA/4KV). Up = 100V.

AT-2217 - ATLAN 4 CAT6

ATLAN 4 CAT6 - Surge protector for category 6 computer networks. 1 GBit/s. RJ45 input/output connectors.UC2 test (2kA/4kV). Up = 150V. Includes 4 cables (CAT6) with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2218 - ATFREQ 12 BNC

ATFREQ 12 BNC - Surge protector for coaxial cables, rack for 12 lines. BNC connectors. Frequency range - 0-1 GHz. Attenuation < 0,15dB. Exchanged Power = 50W. Imax(8/20) = 10kA. DC Sparkover voltage = 90V.

AT-2221 - ATLAN-C 8

ATLAN-C8 - Surge protector for 8 lines for computer networks. 1 GBit/s. RJ45 input/output. C2 Test (2kA/4kV). Up = 100V. Includes 8 cables with RJ45 connectors, 0,5 m long.

AT-2223 - ATLAN 24 POE

ATLAN 24 POE - Surge protection for POE computer networks. 1 GBit/s. RJ45 input/output connectors. C2 Test (2kA/4KV). Up = 200V. Includes 24 cables with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2224 - ATLAN 8 POE

ATLAN 8 POE - Surge protection for POE computer networks. 1 GBit/s. RJ45 input/output connectors. C2 Test (2kA/4KV). Up = 200V. Includes 8 cables with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2225 - ATLAN 16 POE

ATLAN 16 POE - Surge protection for POE computer networks. 1 GBit/s. RJ45 input/output connectors. C2 Test (2kA/4KV). Up = 200V. Includes 16 cables with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2226 - ATLAN 4 CAT6 POE

ATLAN 4 CAT6 POE - Surge protection for category 6, POE computer networks. 1 GBit/s. Protected pairs: 4 x 4. Crimped connector input/RJ45 output. C2 Test (2kA/4KV). Up = 250V. Includes 4 cables (CAT6) with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2227 - ATLAN 8 CAT6 POE

ATLAN 8 CAT6 POE - Surge protection for category 6, POE computer networks. 1 GBit/s. Protected pairs: 8 x 4. Crimped connector input/RJ45 output. C2 Test (2kA/4KV). Up = 250V. Includes 4 cables (CAT6) with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2228 - ATLAN 12 CAT6 POE

ATLAN 12 CAT6 POE - Surge protection for category 6, POE computer networks. 1 GBit/s. Protected pairs: 12 x 4. Crimped connector input/RJ45 output. C2 Test (2kA/4KV). Up = 250V. Includes 4 cables (CAT6) with RJ45 connectors, 0,5 m long and 19'' rack.

AT-2230 - ATLAN 4 PCB CAT6 POE

ATLAN 4 PCB CAT6 POE - Surge protection module for spare parts of the series ATLAN 12/8/4 with 4 CAT6 POE computer lines. 1 GBit/s. Crimped connector input / RJ45 output. C2 Test (2kA/4KV). Up = 250V.

AT-2231 - ATLAN 8 PCB POE

ATLAN 8 PCB POE - Surge protection module for spare parts of the series ATLAN 8/16/24 with 8 POE computer lines. 1 GBit/s. RJ45 input/output connectors. C2 Test (2kA/4KV). Up = 200V.

AT-2300 - ATDB9

ATDB9 - Individual protector for data lines with DB9 type connector. Up = 80V. C2 Test (2kA/4KV).

AT-2515 - DAT CONTROLER® REMOTE 15

DAT CONTROLER® REMOTE 15: Early Streamer Emission air terminal (∆t= 15µs), with remote verification. Material: Stainless steel AISI 316L.

AT-2530 - DAT CONTROLER® REMOTE 30

DAT CONTROLER® REMOTE 30: Early Streamer Emission air terminal (∆t= 30µs), with remote verification. Material: Stainless steel AISI 316L.

AT-2545 - DAT CONTROLER® REMOTE 45

DAT CONTROLER® REMOTE 45: Early Streamer Emission air terminal (∆t= 45µs), with remote verification. Material: Stainless steel AISI 316L.

AT-2560 - DAT CONTROLER® REMOTE 60

DAT CONTROLER® REMOTE 60: Early Streamer Emission air terminal (∆t= 60µs), with remote verification. Material: Stainless steel AISI 316L.

AT-303E - Self-drill double screw

6.3 x 5 mm self - drill double screw with M6 for fixing cable or tape clips to beams and metal structures. Includes ø19 mm neoprene washer.

AT-3501 - RF SPD TESTER

RF SPD TESTER - Tester for checking the state of DIN rail ATFONO, ATLINE and ATVOLT protection modules.

AT-8000 - ATSUB-4P 15 TNS

ATSUB-4P 15 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2+3. Uc = 460 VAC (L-L). Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8001 - ATSUB-4P 40 TNS

ATSUB-4P 40 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2. Uc = 460 VAC (L-L). Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8002 - ATSUB-4P 65 TNS

ATSUB-4P 65 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 1+2. Uc = 460 VAC (L-L). Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8003 - ATSUB-4P 15-120 TNS

ATSUB-4P 15-120 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2+3. Uc = 275 VAC (L-L). Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8004 - ATSUB-4P 40-120 TNS

ATSUB-4P 40-120 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2. Uc = 275 VAC (L-L). Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8005 - ATSUB-4P 65-120 TNS

ATSUB-4P 65-120 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 1+2. Uc = 275 VAC (L-L). Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8006 - ATSUB-4P 15-400 TNS

ATSUB-4P 15-400 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2+3. Uc = 800 VAC (L-L). Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 4DIN.

AT-8007 - ATSUB-4P 40-400 TNS

ATSUB-4P 40-400 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2. Uc = 800 VAC (L-L). Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 4DIN.

AT-8009 - ATSUB-2P 40 TN

ATSUB-2P 40 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8010 - ATSUB-2P 15 TN

ATSUB-2P 15 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8011 - ATSUB-2P 65 TN

ATSUB-2P 65 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8012 - ATSUB-2P 15-120 TN

ATSUB-2P 15-120 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2+3. Uc = 150 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8013 - ATSUB-2P 40-120 TN

ATSUB-2P 40-120 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2. Uc = 150 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8014 - ATSUB-2P 65-120 TN

ATSUB-2P 65-120 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 1+2. Uc = 150 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8015 - ATSUB-2P 15-400 TN

ATSUB-2P 15-400 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2+3. Uc = 460 VAC. Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 2DIN.

AT-8016 - ATSUB-2P 40-400 TN

ATSUB-2P 40-400 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2. Uc = 460 VAC. Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 2DIN.

AT-8017 - ATSUB 40-D T

ATSUB40-D T - Protector for power supply lines. 4-pole. Type 2. Uc = 800 VAC (L-L). Imax =40 kA. Up(In) = 1800 V. Size 2DIN.

AT-8020 - ATSUB-2P-NR 40 TT

ATSUB-2P-NR 40 TT - Protector for TT power supply lines. Protection neutral-earth. With pluggable module. 2-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8021 - ATSUB-D M 3/4 DIN-120

ATSUB-D M ¾ DIN-120 - Protector for power supply lines. Protection neutral-earth. With pluggable module. 2-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1000 V. Size 3DIN.

AT-8026 - ATSUB-2P-NR 65 TT

ATSUB-2P-NR 65 TT - Protector for TT power supply lines. Protection neutral-earth. With pluggable module. 2-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8027 - ATSUB-D M 3/4DIN-120 Mod.

ATSUB-D M ¾DIN-120 Mod. - Protector for power supply lines. Spare pluggable module. With pluggable module. Single-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1000 V. Size ¾ DIN.

AT-8030 - ATSUB-4P-NR 40 TT

ATSUB-4P-NR 40 TT - Protector for TT power supply lines. Protection neutral-earth. With pluggable module. 4-pole. Type 2. Uc = 460 VAC (L-L). Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8034 - ATSUB-4P-NR 15 TT

ATSUB-4P-NR 15 TT - Protector for TT power supply lines. Protection neutral-earth. With pluggable module. 4-pole. Type 2+3. Uc = 460 VAC (L-L). Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8035 - ATSUB-2P-NR 15 TT

ATSUB-2P-NR 15 TT - Protector for TT power supply lines. Protection neutral-earth. With pluggable module. 2-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8036 - ATSUB-4P-NR 65 TT

ATSUB-4P-NR 65 TT - Protector for TT power supply lines. Protection neutral-earth. With pluggable module. 4-pole. Type 1+2. Uc = 460 VAC (L-L). Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8037 - ATSUB-3P-NR 15-120

ATSUB-3P-NR 15-120 - Protector for 2-phase power supply lines. Protection neutral-earth. With pluggable module. 3-pole. Type 2+3. Uc = 275 VAC (L-L). Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 3DIN.

AT-8038 - ATSUB-3P-NR 40-120

ATSUB-3P-NR 40-120 - Protector for 2-phase power supply lines. Protection neutral-earth. With pluggable module. 3-pole. Type 2. Uc = 275 VAC (L-L). Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 3DIN.

AT-8039 - ATSUB-3P-NR 65-120

ATSUB-3P-NR 65-120 - Protector for 2-phase power supply lines. Protection neutral-earth. With pluggable module. 3-pole. Type 1+2. Uc = 275 VAC (L-L). Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 3DIN.

AT-8043 - ATSUB Mod. 40-300

ATSUB Mod. 40-300 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8044 - ATSUB Mod. 15-300

ATSUB Mod. 15-300 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8045 - ATSUB Mod. 65-300

ATSUB Mod. 65-300 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 1+2. Uc = 320 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 1DIN.

AT-8047 - ATSUB-2P 15-300 TT

ATSUB-2P 15-300 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8048 - ATSUB-2P 40-300 TT

ATSUB-2P 40-300 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2. Uc = 320 VAC. Imax =40 kA. Up(In) = 1500 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8049 - ATSUB-2P 65-300 TT

ATSUB-2P 65-300 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 1+2. Uc = 320 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 2DIN.

AT-8050 - ATSUB-4P 15 -300 TNS

ATSUB-4P 15 -300 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2+3. Uc = 555 VAC (L-L). Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8051 - ATSUB-4P 40-300 TNS

ATSUB-4P 40-300 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2. Uc = 555 VAC (L-L). Imax =40 kA. Up(In) = 1500 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8052 - ATSUB-4P 65-300 TNS

ATSUB-4P 65-300 TNS - Protector for TNS power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 1+2. Uc = 555 VAC (L-L). Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 4DIN.

AT-8053 - ATSUB-2P 15-300 TN

ATSUB-2P 15-300 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8054 - ATSUB-2P 40-300 TN

ATSUB-2P 40-300 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2. Uc = 320 VAC. Iimp = 15 kA. Imax =40 kA. Up(In) = 1500 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8055 - ATSUB-2P 65-300 TN

ATSUB-2P 65-300 TN - Protector for TN power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 1+2. Uc = 320 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 2DIN.

AT-8056 - ATSUB-P 15-300

ATSUB-P 15-300 - Protector for power supply lines. With pluggable module. Single-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8057 - ATSUB-P 40-300

ATSUB-P 40-300 - Protector for power supply lines. With pluggable module. Single-pole. Type 2. Uc = 320 VAC. Imax =40 kA. Up(In) = 1500 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8058 - ATSUB-P 65-300

ATSUB-P 65-300 - Protector for power supply lines. With pluggable module. Single-pole. Type 1+2. Uc = 320 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 1DIN.

AT-8059 - ATSUB-PR 15-300

ATSUB-PR 15-300 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8060 - ATSUB-PR 40-300

ATSUB-PR 40-300 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 2. Uc = 320 VAC. Imax =40 kA. Up(In) = 1500 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8061 - ATSUB-PR 65-300

ATSUB-PR 65-300 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 1+2. Uc = 320 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 1DIN.

AT-8062 - ATSUB 15-300

ATSUB 15-300 - Protector for power supply lines. Single-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8063 - ATSUB 40-300

ATSUB 40-300 - Protector for power supply lines. Single-pole. Type 2. Uc = 320 VAC. Imax =40 kA. Up(In) = 1500 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8064 - ATSUB 65-300

ATSUB 65-300 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 320 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 1DIN.

AT-8065 - ATSUB-R 15-300

ATSUB-R 15-300 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8066 - ATSUB-R 40-300

ATSUB-R 40-300 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 2. Uc = 320 VAC. Imax =40 kA. Up(In) = 1500 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8067 - ATSUB-R 65-300

ATSUB-R 65-300 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 1+2. Uc = 320 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 1DIN.

AT-8070 - ATSUB-3P-NR 15 TNC

ATSUB-3P-NR 15 TNC - Protector for TNC power supply lines. With pluggable module. 3-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 3DIN.

AT-8071 - ATSUB-3P-NR 40 TNC

ATSUB-3P-NR 40 TNC - Protector for TNC power supply lines. With pluggable module. 3-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 3DIN.

AT-8072 - ATSUB-3P-NR 65 TNC

ATSUB-3P-NR 65 TNC - Protector for TNC power supply lines. With pluggable module. 3-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 3DIN.

AT-8073 - ATSUB-3P-NR 15-120 TNC

ATSUB-3P-NR 15-120 TNC - Protector for TNC power supply lines. Protection neutral-earth. With pluggable module. 3-pole. Type 2+3. Uc = 150 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 3DIN.

AT-8074 - ATSUB-3P-NR 40-120 TNC

ATSUB-3P-NR 40-120 TNC - Protector for TNC power supply lines. Protection neutral-earth. With pluggable module. 3-pole. Type 2. Uc = 150 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 3DIN.

AT-8075 - ATSUB-3P-NR 65-120 TNC

ATSUB-3P-NR 65-120 TNC - Protector for TNC power supply lines. Protection neutral-earth. With pluggable module. 3-pole. Type 1+2. Uc = 150 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 3DIN.

AT-8111 - ATCOVER 130M

ATCOVER 130M - Surge protection of three phases, neutral and earth for three-phase, 130V(L-T) power supply lines. Imax(8/20) = 30kA. Up = 700V.

AT-8112 - ATCOVER 230M

ATCOVER 230M - Surge protection of phase, neutral and earth for single-phase, 230V(L-T) power supply lines. Imax(8/20) = 30kA. Up = 900V.

AT-8113 - ATCOMBO 230M

ATCOMBO 230M - Surge protector for 230V single-phase lines with Schuko connector in a watertight proof box. Imax = 30kA. Up = 900V.

AT-8114 - ATBARRIER MFF

ATBARRIER MFF - Full coordinated surge protection cabinet for single-phase power supply lines. Formed by ATSHOCK + ATCOVER. Iimp = 50kA. Up = 900V.

AT-8115 - ATCOMBO 130M

ATCOMBO 130M - Surge protector for 130V single-phase lines with Schuko connector in a watertight proof box. Imax = 30kA. Up = 900V.

AT-8117 - ATCOMPACT M2 15kA

ATCOMPACT M2 15kA - Type 2 surge protection cabinet for single-phase power supply lines. Imax = 15kA. Up = 1,2kV. Includes protection fuses.

AT-8118 - ATBARRIER MM

ATBARRIER MM - Full coordinated surge protection cabinet for single-phase power supply lines. Formed by ATSHOCK + ATSUB40. Iimp = 50kA. Up = 1,4kV.

AT-8119 - ATCOMPACT M2 65kA

ATCOMPACT M2 65kA - Type 2 surge protection cabinet for single-phase power supply lines. Imax = 65kA. Up = 1,6kV. Includes protection fuses.

AT-8120 - ATCOMPACT T2 65kA

ATCOMPACT T2 65kA - Type 2 surge protection cabinet for three-phase power supply lines. Imax = 65kA. Up = 1,6kV. Includes protection fuses.

AT-8121 - ATBARRIER TM

ATBARRIER TM - Full coordinated surge protection cabinet for three-phase power supply lines. Formed by ATSHOCK + ATSUB40. Iimp = 50kA. Up = 1,4kV.

AT-8122 - ATCOMPACT T2 15kA

ATCOMPACT T2 15kA - Type 2 surge protection cabinet for three-phase power supply lines. Imax = 15kA. Up = 1,2kV. Includes protection fuses.

AT-8125 - ATBARRIER MF

ATBARRIER MF - Full coordinated surge protection cabinet for single-phase power supply lines. Formed by ATSHOCK + ATSUB15. Iimp = 50kA. Up = 1,2kV.

AT-8130 - ATCOMPACT T2 30kA

ATCOMPACT T2 30kA - Type 2 surge protection cabinet for three-phase power supply lines. Imax = 30kA. Up = 900V. Includes protection fuses.

AT-8131 - ATCOMPACT M2 30kA

ATCOMPACT M2 30kA - Type 2 surge protection cabinet for single-phase power supply lines. Imax = 30kA. Up = 900V. Includes protection fuses.

AT-8132 - ATCOVER 230T

ATCOVER 230T - Protection of three phases, neutral and earth for three-phase, 230V(L-L) power supply lines. Imax(8/20) = 30kA. Up = 700V.

AT-8133 - ATCOVER 400T

ATCOVER 400T - Surge protection of three phases, neutral and earth for three-phase, 400V(L-L) power supply lines. Imax(8/20) = 30kA. Up = 900V.

AT-8134 - ATBARRIER TFF

ATBARRIER-TFF - Full coordinated surge protection cabinet for three-phase power supply lines. Formed by ATSHOCK + ATCOVER. Iimp = 50kA. Up = 900V.

AT-8139 - ATCOMPACT M2 40kA

ATCOMPACT M2 40kA - Type 2 surge protection cabinet for single-phase power supply lines. Imax = 40kA. Up = 1,4kV. Includes protection fuses.

AT-8140 - ATCOMPACT T2 40kA

ATCOMPACT T2 40kA - Type 2 surge protection cabinet for three-phase power supply lines. Imax = 40kA. Up = 1,4kV. Includes protection fuses.

AT-8141 - ATBARRIER TF

ATBARRIER-TF - Full coordinated surge protection cabinet for three-phase power supply lines. Formed by ATSHOCK + ATSUB15. Iimp = 50kA. Up = 1,2kV.

AT-8149 - ATCOMPACT M1 50kA

ATCOMPACT M1 50 kA - Surge protection cabinet for single-phase power supply lines. Type 1. Imax = 50kA. Up = 2,5kV. Includes protection fuses.

AT-8150 - ATCOMPACT T1 50kA

ATCOMPACT T1 50 kA - Surge protection cabinet for three-phase power supply lines. Type 1. Iimp = 50kA. Up = 2,5kV. Includes protection fuses.

AT-8152 - ATCOVER TNC 230T

ATCOVER TNC 230T - Multipole surge protection for three-phase, 230V(L-L) power supply lines without neutral. Imax = 30kA. Up = 700V.

AT-8153 - ATCOVER TNC 400T

ATCOVER TNC 400T - Multipole surge protection for three-phase, 400V(L-L) power supply lines without neutral. Imax = 30kA. Up = 900V.

AT-8160 - ATCOMPACT T1 30kA

ATCOMPACT T1 30 kA - Surge protection cabinet for three-phase power supply lines. Type 1. Iimp = 30kA. Up = 1,5kV. Includes protection fuses.

AT-8161 - ATCOMPACT M1 30kA

ATCOMPACT M1 30 kA - Surge protection cabinet for single-phase power supply lines. Type 1. Iimp = 30kA. Up = 1,5kV. Includes protection fuses.

AT-8190 - ATCOMPACT CDA T1 15 kA

ATCOMPACT CDA T1 15 kA - Box with double isolemente (36 x 27 cm) for protecting three-phase lines. Type 1+2. Imax = 65kA. Iimp = 15kA. Up = 1,6kV. Includes 80A protection fuses and fuse holders.

AT-8191 - ATCOMPACT CDA T1 25kA

ATCOMPACT CDA T1 25 kA - Box with double isolemente (36 x 27 cm) for protecting three-phase lines. Type 1+2. Imax(8/20) = 100kA. Iimp = 25kA. Up = 1,5kV. Includes 80A protection fuses and fuse holders.

AT-8192 - ATCOMPACT CDA T1 30kA

ATCOMPACT CDA T1 30kA - Box with double isolemente (36 x 27 cm) for protecting three-phase lines. Type 1. Iimp (L-N)= 30kA, Iimp (N-PE)=100 kA. Up (L-N) = 2kV, Up (N-PE) = 900V. Includes 80A protection fuses and fuse holders.

AT-8200 - ATSUB-D M 1DIN

ATSUB-D M 1DIN - Protector for power supply lines. 2-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1500 V. Size 1DIN.

AT-8201 - ATSUB N

ATSUB N - Protector for power supply lines. Protection neutral-earth. Single-pole. Type 2. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8202 - ATSUB-P N

ATSUB-P N - Protector for power supply lines. Protection neutral-earth. With pluggable module. Single-pole. Type 2. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8203 - ATSUB-PR N

ATSUB-PR N - Protector for power supply lines. Protection neutral-earth. With pluggable module. Connection for remote warning. Single-pole. Type 2. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8204 - ATSUB-R N

ATSUB-R N - Protector for power supply lines. Protection neutral-earth. Connection for remote warning. Single-pole. Type 2. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8205 - ATSUB Mod. N

ATSUB Mod. N - Protector for power supply lines. Spare pluggable module. Protection neutral-earth. Single-pole. Type 2. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8206 - ATSUB-4P 15-300 TT

ATSUB-4P 15-300 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2+3. Uc = 555 VAC (L-L). Imax =15 kA. Up(In) = 1400 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8207 - ATSUB-4P 40-300 TT

ATSUB-4P 40-300 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2. Uc = 555 VAC (L-L). Imax =40 kA. Up(In) = 1500 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8208 - ATSUB-R 40-120

ATSUB-R 40-120 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 2. Uc = 150 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8209 - ATSUB-R 65-120

ATSUB-R 65-120 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 1+2. Uc = 150 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8210 - ATSUB-D M 3/4DIN Mod.

ATSUB-D M ¾DIN Mod. - Protector for power supply lines. Spare pluggable module. Single-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1500 V. Size ¾ DIN.

AT-8213 - ATSUB 140-400

ATSUB 140-400 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 460 VAC. Iimp = 30 kA. Imax =140 kA. Up(1,2/50) = 1500 V. Size 4DIN.

AT-8214 - ATSUB 140-230

ATSUB 140-230 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 275 VAC. Iimp = 30 kA. Imax =140 kA. Up(1,2/50) = 900 V. Size 4DIN.

AT-8215 - ATSUB 140-130

ATSUB 140-130 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 150 VAC. Iimp = 30 kA. Imax =140 kA. Up(1,2/50) = 500 V. Size 4DIN.

AT-8216 - ATSUB-D M

ATSUB-D M - Protector for power supply lines. 4-pole. Type 2+3. Uc = 400 VAC. Imax =15 kA. Up(In) = 1500 V. Up(1,2/50) = 1100 V. Size 2DIN.

AT-8217 - ATSUB-D T

ATSUB-D T - Protector for power supply lines. 4-pole. Type 2. Uc = 800 VAC (L-L). Imax =15 kA. Up(In) = 1500 V. Size 2DIN.

AT-8218 - ATSUB 140-N

ATSUB 140-N - Protector for power supply lines. Protection neutral-earth. Single-pole. Type 1+2. Iimp = 30 kA. Imax =140 kA. Up(1,2/50) = 900 V. Size 4DIN.

AT-8219 - ATSUB-D M 3/4 DIN

ATSUB-D M ¾ DIN - Protector for power supply lines. Protection neutral-earth. 2-pole. Type 2+3. Uc = 320 VAC. Imax =15 kA. Up(In) = 1500 V. Size 3DIN.

AT-8220 - ATSUB 15

ATSUB 15 - Protector for power supply lines. Single-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8221 - ATSUB-R 15

ATSUB-R 15 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8222 - ATSUB-P 15

ATSUB-P 15 - Protector for power supply lines. With pluggable module. Single-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8223 - ATSUB-PR 15

ATSUB-PR 15 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8224 - ATSUB 15-400

ATSUB 15-400 - Protector for power supply lines. Single-pole. Type 2+3. Uc = 460 VAC. Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8225 - ATSUB-R 15-400

ATSUB-R 15-400 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 2+3. Uc = 460 VAC. Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8226 - ATSUB-P 15-400

ATSUB-P 15-400 - Protector for power supply lines. With pluggable module. Single-pole. Type 2+3. Uc = 460 VAC. Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8227 - ATSUB-PR 15-400

ATSUB-PR 15-400 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 2+3. Uc = 460 VAC. Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8228 - ATSUB Mod. 15

ATSUB Mod. 15 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8229 - ATSUB Mod. 15-400

ATSUB Mod. 15-400 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 2+3. Uc = 460 VAC. Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8230 - ATSUB 15-120

ATSUB 15-120 - Protector for power supply lines. Single-pole. Type 2+3. Uc = 150 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8232 - ATSUB-2P 15 TT

ATSUB-2P 15 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2+3. Uc = 275 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8233 - ATSUB-2P 15-400 TT

ATSUB-2P 15-400 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2+3. Uc = 460 VAC. Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 2DIN.

AT-8234 - ATSUB-2P 15-120 TT

ATSUB-2P 15-120 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2+3. Uc = 150 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8235 - ATSUB-2P 40 TT

ATSUB-2P 40 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8236 - ATSUB-2P 40-400 TT

ATSUB-2P 40-400 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2. Uc = 460 VAC. Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 2DIN.

AT-8237 - ATSUB-2P 40-120 TT

ATSUB-2P 40-120 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 2. Uc = 150 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 2DIN.

AT-8238 - ATSUB-2P 65 TT

ATSUB-2P 65 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8239 - ATSUB-4P 65-300 TT

ATSUB-4P 65-300 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 1+2. Uc = 555 VAC (L-L). Iimp = 15 kA. Imax =65 kA. Up(In) = 1800 V. Up(1,2/50) = 1100 V. Size 4DIN.

AT-8240 - ATSUB 40

ATSUB 40 - Protector for power supply lines. Single-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8241 - ATSUB-R 40

ATSUB-R 40 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8242 - ATSUB-P 40

ATSUB-P 40 - Protector for power supply lines. With pluggable module. Single-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8243 - ATSUB-PR 40

ATSUB-PR 40 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8244 - ATSUB 40-400

ATSUB 40-400 - Protector for power supply lines. Single-pole. Type 2. Uc = 460 VAC. Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8245 - ATSUB-R 40-400

ATSUB-R 40-400 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 2. Uc = 460 VAC. Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8246 - ATSUB-P 40-400

ATSUB-P 40-400 - Protector for power supply lines. With pluggable module. Single-pole. Type 2. Uc = 460 VAC. Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8247 - ATSUB-PR 40-400

ATSUB-PR 40-400 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 2. Uc = 460 VAC. Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8248 - ATSUB Mod. 40

ATSUB Mod. 40 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 2. Uc = 275 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8249 - ATSUB Mod. 40-400

ATSUB Mod. 40-400 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 2. Uc = 460 VAC. Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 1DIN.

AT-8250 - ATSUB 40-120

ATSUB 40-120 - Protector for power supply lines. Single-pole. Type 2. Uc = 150 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8256 - ATSUB 100

ATSUB 100 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 275 VAC. Iimp = 25 kA. Imax =100 kA. Up(1,2/50) = 1,3 kV. Size 2DIN.

AT-8257 - ATSUB 100-120

ATSUB 100-120 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 150 VAC. Iimp = 25 kA. Imax =100 kA. Up(1,2/50) = 0,9 kV. Size 2DIN.

AT-8258 - ATSUB 100-400

ATSUB 100-400 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 460 VAC. Iimp = 25 kA. Imax =100 kA. Up(1,2/50) = 1,5 kV. Size 2DIN.

AT-8259 - ATSUB 100-N

ATSUB 100-N - Protector for power supply lines. Protection neutral-earth. Single-pole. Type 1+2. Iimp = 25 kA. Imax =100 kA. Up(1,2/50) = 1,3 kV. Size 2DIN.

AT-8260 - ATSUB 65

ATSUB 65 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8261 - ATSUB-R 65

ATSUB-R 65 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8262 - ATSUB-P 65

ATSUB-P 65 - Protector for power supply lines. With pluggable module. Single-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8263 - ATSUB-PR 65

ATSUB-PR 65 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8264 - ATSUB 65-400

ATSUB 65-400 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 460 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 2500 V. Up(1,2/50) = 1900 V. Size 1DIN.

AT-8265 - ATSUB-R 65-400

ATSUB-R 65-400 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 1+2. Uc = 460 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 2500 V. Up(1,2/50) = 1900 V. Size 1DIN.

AT-8268 - ATSUB Mod. 65

ATSUB Mod. 65 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 1+2. Uc = 275 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8270 - ATSUB 65-120

ATSUB 65-120 - Protector for power supply lines. Single-pole. Type 1+2. Uc = 150 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8280 - ATSUB-2P 65-120 TT

ATSUB-2P 65-120 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 2-pole. Type 1+2. Uc = 150 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 2DIN.

AT-8281 - ATSUB-4P 15-400 TT

ATSUB-4P 15-400 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2+3. Uc = 800 VAC (L-L). Imax =15 kA. Up(In) = 2100 V. Up(1,2/50) = 1800 V. Size 4DIN.

AT-8282 - ATSUB-4P 15 TT

ATSUB-4P 15 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2+3. Uc = 460 VAC (L-L). Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8283 - ATSUB-4P 15-120 TT

ATSUB-4P 15-120 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2+3. Uc = 275 VAC (L-L). Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8284 - ATSUB-4P 40-400 TT

ATSUB-4P 40-400 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2. Uc = 800 VAC (L-L). Imax =40 kA. Up(In) = 2300 V. Up(1,2/50) = 1800 V. Size 4DIN.

AT-8285 - ATSUB-4P 40 TT

ATSUB-4P 40 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2. Uc = 460 VAC (L-L). Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8286 - ATSUB-4P 40-120 TT

ATSUB-4P 40-120 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 2. Uc = 275 VAC (L-L). Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 4DIN.

AT-8287 - ATSUB-4P 65 TT

ATSUB-4P 65 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 1+2. Uc = 460 VAC (L-L). Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8289 - ATSUB-4P 65-120 TT

ATSUB-4P 65-120 TT - Protector for TT power supply lines. With pluggable module. Connection for remote warning. 4-pole. Type 1+2. Uc = 275 VAC (L-L). Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 4DIN.

AT-8290 - ATSUB-P 15-120

ATSUB-P 15-120 - Protector for power supply lines. With pluggable module. Single-pole. Type 2+3. Uc = 150 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8291 - ATSUB-P 40-120

ATSUB-P 40-120 - Protector for power supply lines. With pluggable module. Single-pole. Type 2. Uc = 150 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8292 - ATSUB-P 65-120

ATSUB-P 65-120 - Protector for power supply lines. With pluggable module. Single-pole. Type 1+2. Uc = 150 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8293 - ATSUB-PR 15-120

ATSUB-PR 15-120 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 2+3. Uc = 150 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8294 - ATSUB-PR 40-120

ATSUB-PR 40-120 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 2. Uc = 150 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8295 - ATSUB-PR 65-120

ATSUB-PR 65-120 - Protector for power supply lines. With pluggable module. Connection for remote warning. Single-pole. Type 1+2. Uc = 150 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8296 - ATSUB Mod. 40-120

ATSUB Mod. 40-120 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 2. Uc = 150 VAC. Imax =40 kA. Up(In) = 1400 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8297 - ATSUB Mod. 15-120

ATSUB Mod. 15-120 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 2+3. Uc = 150 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8298 - ATSUB Mod. 65-120

ATSUB Mod. 65-120 - Protector for power supply lines. Spare pluggable module. Single-pole. Type 1+2. Uc = 150 VAC. Iimp = 15 kA. Imax =65 kA. Up(In) = 1600 V. Up(1,2/50) = 900 V. Size 1DIN.

AT-8299 - ATSUB-R 15-120

ATSUB-R 15-120 - Protector for power supply lines. Connection for remote warning. Single-pole. Type 2+3. Uc = 150 VAC. Imax =15 kA. Up(In) = 1200 V. Up(1,2/50) = 700 V. Size 1DIN.

AT-8310 - ATSHOCK L30

ATSHOCK L30 - Protector for power supply lines. Single-pole. Type 1. Uc = 275 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8311 - ATSHOCK L30-130

ATSHOCK L30-130 - Protector for power supply lines. Single-pole. Type 1. Uc = 150 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8312 - ATSHOCK L30-400

ATSHOCK L30-400 - Protector for power supply lines. Single-pole. Type 1. Uc = 460 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8325 - ATSHOCK L25

ATSHOCK L25 - Protector for power supply lines. Single-pole. Type 1 + 2. Uc = 275 VAC. Iimp(10/350) = 25 kA. Up = 1,5 kV. Size 2 DIN.

AT-8326 - ATSHOCK L25-130

ATSHOCK L25-130 - Protector for power supply lines. Single-pole. Type 1 + 2. Uc = 150 VAC. Iimp(10/350) = 25 kA. Up = 1,5 kV. Size 2 DIN.

AT-8330 - ATSHOCK-P L30

ATSHOCK-P L30 - Protector for power supply lines. Pluggable. Single-pole. Type 1. Uc = 275 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8331 - ATSHOCK-P L30-130

ATSHOCK-P L30-130 - Protector for power supply lines. Pluggable. Single-pole. Type 1. Uc = 150 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8332 - ATSHOCK-P L30-400

ATSHOCK-P L30-400 - Protector for power supply lines. Pluggable. Single-pole. Type 1. Uc = 460 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8333 - ATSHOCK-P L30 Mod.

ATSHOCK-P L30 Mod. - Protector for power supply lines. Pluggable module for protecting the line. Type 1. Uc = 275 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8334 - ATSHOCK-P L30-130 Mod.

ATSHOCK-P L30-130 Mod. - Protector for power supply lines. Pluggable module for protecting the line. Type 1. Uc = 150 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8335 - ATSHOCK-P L30-400 Mod.

ATSHOCK-P L30-400 Mod. - Protector for power supply lines. Pluggable module for protecting the line. Type 1. Uc = 460 VAC. Iimp(10/350) = 30 kA. Up = 2 kV. Size 2 DIN.

AT-8336 - ATSHOCK-P N60 Mod.

ATSHOCK-P N60 Mod. - Protector for power supply lines. Pluggable module for protecting the neutral. Type 1. Iimp(10/350) = 60 kA. Up = 900 V. Size 2 DIN.

AT-8350 - ATSHOCK L

ATSHOCK L - Protector for power supply lines. Single-pole. Type 1. Uc = 275 VAC. Iimp(10/350) = 50 kA. Up = 2,5 kV. Size 2 DIN.

AT-8351 - ATSHOCK L-120

ATSHOCK L-120 - Protector for power supply lines. Single-pole. Type 1. Uc = 150 VAC. Iimp(10/350) = 50 kA. Up = 2,5 kV. Size 2 DIN.

AT-8352 - ATSHOCK L-400

ATSHOCK L-400 - Protector for power supply lines. Single-pole. Type 1. Uc = 460 VAC. Iimp(10/350) = 50 kA. Up = 2,5 kV. Size 2 DIN.

AT-8397 - ATSHOCK-P N60

ATSHOCK-P N60 - Protector for power supply lines. Protection neutral - earth. Pluggable. Single-pole. Type 1. Iimp(10/350) = 60 kA. Up = 900 V. Size 2 DIN.

AT-8398 - ATSHOCK N60

ATSHOCK N60 - Protector for power supply lines. Protection neutral - earth. Single-pole. Type 1. Iimp(10/350) = 60 kA. Up = 900 V. Size 2 DIN.

AT-8399 - ATSHOCK N

ATSHOCK N - Protector for power supply lines. Protection neutral - earth. Single-pole. Type 1. Iimp(10/350) = 100 kA. Up = 1,5 kV. Size 2 DIN.

AT-8435 - ATLINK 35

ATLINK 35 - Decoupling inductor for SPD coordination in power supply lines with If < 35A. L = 15 μH.

AT-8463 - ATLINK 63

ATLINK 63 - Decoupling inductor for SPD coordination in power supply lines with If < 63A. L = 15 μH.

AT-8505 - ATVOLT 5

ATVOLT 5 - SPD for the protection of DC lines with Un = 5VDC. In = 5kA. Up = 100V.

AT-8506 - ATVOLT 5 Mod.

ATVOLT 5 Mod. - Pluggable module for surge protectors of DC lines with Un = 5VDC. In = 5kA. Up = 100V.

AT-8510 - ATVOLT 110

ATVOLT 110 - SPD for the protection of DC lines with Un = 110VDC. In = 5kA. Up = 400V.

AT-8511 - ATVOLT 110 Mod.

ATVOLT 110 Mod. - Pluggable module for surge protectors of DC lines with Un = 110VDC. In = 5kA. Up = 400V.

AT-8512 - ATVOLT 12

ATVOLT 12 - SPD for the protection of DC lines with Un = 12VDC. In = 5kA. Up = 100V.

AT-8513 - ATVOLT 12 Mod.

ATVOLT 12 Mod. - Pluggable module for surge protectors of DC lines with Un = 12VDC. In = 5kA. Up = 100V.

AT-8514 - ATVOLT P12

ATVOLT P12 - SPD for the protection of DC lines with Un = 12VDC. In = 10kA. Up = 570V. To be installed in parallel.

AT-8515 - ATVOLT 15

ATVOLT 15 - SPD for the protection of DC lines with Un = 15VDC. In = 5kA. Up = 100V.

AT-8516 - ATVOLT 15 Mod.

ATVOLT 15 Mod. - Pluggable module for surge protectors of DC lines with Un = 15VDC. In = 5kA. Up = 100V.

AT-8524 - ATVOLT 24

ATVOLT 24 - SPD for the protection of DC lines with Un = 24VDC. In = 5kA. Up = 120V.

AT-8525 - ATVOLT 24 Mod.

ATVOLT 24 Mod. - Pluggable module for surge protectors of DC lines with Un = 24VDC. In = 5kA. Up = 120V.

AT-8526 - ATVOLT P24

ATVOLT P24 - SPD for the protection of DC lines with Un = 24VDC. In = 10kA. Up = 630V. To be installed in parallel.

AT-8530 - ATVOLT 30

ATVOLT 30 - SPD for the protection of DC lines with Un = 30VDC. In = 5kA. Up = 150V.

AT-8531 - ATVOLT 30 Mod.

ATVOLT 30 Mod. - Pluggable module for surge protectors of DC lines with Un = 30VDC. In = 5kA. Up = 150V.

AT-8548 - ATVOLT 48

ATVOLT 48 - SPD for the protection of DC lines with Un = 48VDC. In = 5kA. Up = 240V.

AT-8549 - ATVOLT P48

ATVOLT P48 - SPD for the protection of DC lines with Un = 48VDC. In = 10kA. Up = 730V. To be installed in parallel.

AT-8550 - ATVOLT 48 Mod.

ATVOLT 48 Mod. - Pluggable module for surge protectors of DC lines with Un = 48VDC. In = 5kA. Up = 240V.

AT-8560 - ATVOLT 60

ATVOLT 60 - SPD for the protection of DC lines with Un = 60VDC. In = 5kA. Up = 300V.

AT-8561 - ATVOLT 60 Mod.

ATVOLT 60 Mod. - Pluggable module for surge protectors of DC lines with Un = 60VDC. In = 5kA. Up = 300V.

AT-8580 - ATVOLT 80

ATVOLT 80 - SPD for the protection of DC lines with Un = 80VDC. In = 5kA. Up = 400V.

AT-8581 - ATVOLT 80 Mod.

ATVOLT 80 Mod. - Pluggable module for surge protectors of DC lines with Un = 80VDC. In = 5kA. Up = 400V.

AT-8590 - ATVOLT P5

ATVOLT P5 - SPD for the protection of DC lines with Un = 5VDC. In = 10kA. Up = 500V. To be installed in parallel.

AT-8603 - ATSHIELD 400T

ATSHIELD 400T - Protector for TT type power supply lines. Pluggable. 4-pole. Type 1 + 2. Uc = 460 VAC (L-L); 275 VAC (L-N, L-GND). In = 40 kA. Iimp(10/350) = 25 kA. Up = 1,5 kV. Size 8 DIN.

AT-8604 - ATSHIELD 230T

ATSHIELD 230T - Protector for TT type power supply lines. Pluggable. 4-pole. Type 1 + 2. Uc = 275 VAC (L-L); 150 VAC (L-N, L-GND). In = 40 kA. Iimp(10/350) = 25 kA. Up = 1,5 kV. Size 8 DIN.

AT-8607 - ATSHIELD 230M

ATSHIELD 230M - Protector for single-phase power supply lines. Pluggable. 2-pole. Type 1 + 2. Uc = 275 VAC. In = 40 kA. Iimp(10/350) = 25 kA. Up = 1,5 kV. Size 4 DIN.

AT-8608 - ATSHIELD 130M

ATSHIELD 130M - Protector for single-phase power supply lines. Pluggable. 2-pole. Type 1 + 2. Uc = 150 VAC. In = 40 kA. Iimp(10/350) = 25 kA. Up = 1,5 kV. Size 4 DIN.

AT-8611 - ATSHIELD L Mod.

ATSHIELD L Mod. - Protector for power supply lines. Pluggable module for protecting the line. Type 1 + 2. Uc = 275 VAC. In = 40 kA. Iimp(10/350) = 25 kA. Up = 1,5 kV. Size 2 DIN.

AT-8612 - ATSHIELD L-130 Mod.

ATSHIELD L-130 Mod. - Protector for power supply lines. Pluggable module for protecting the line. Type 1 + 2. Uc = 150 VAC. In = 40 kA. Iimp(10/350) = 25 kA. Up = 1,5 kV. Size 2 DIN.

AT-8613 - ATSHIELD N Mod.

ATSHIELD N Mod. - Protector for power supply lines. Pluggable module for protecting the neutral. Type 1 + 2. Iimp(10/350) = 75 kA. Size 2 DIN.

AT-8616 - ATSHIELD TT 400T

ATSHIELD TT 400T - Protector for TT type power supply lines. 4-pole. Type 1 + 2. Uc = 460 VAC (L-L); 275 VAC (L-N, L-GND). In = 40 kA. Iimp(10/350) = 30 kA. Up = 1,5 kV. Size 8 DIN.

AT-8617 - ATSHIELD TT 230T

ATSHIELD TT 230T - Protector for TT type power supply lines. 4-pole. Type 1 + 2. Uc = 275 VAC (L-L); 150 VAC (L-N, L-GND). In = 40 kA. Iimp(10/350) = 30 kA. Up = 1,5 kV. Size 8 DIN.

AT-8618 - ATSHIELD S 230M

ATSHIELD S 230M - Protector for single-phase power supply lines. 2-pole. Type 1 + 2. Uc = 275 VAC. In = 40 kA. Iimp(10/350) = 30 kA. Up = 1,5 kV. Size 4 DIN.

AT-8619 - ATSHIELD S 130M

ATSHIELD S 130M - Protector for single-phase power supply lines. 2-pole. Type 1 + 2. Uc = 150 VAC. In = 40 kA. Iimp(10/350) = 30 kA. Up = 1,5 kV. Size 4 DIN.

AT-8701 - ATCONTROL/B P-T

ATCONTROL/B P-T - Three-phase protector against permanent and transient overvoltages, tripping any shunt release. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8702 - ATCONTROL/B PT-T

ATCONTROL/B PT-T - Three-phase protector against permanent and transient overvoltages, tripping any shunt release. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8703 - ATCONTROL/B P-M

ATCONTROL/B P-M - Single-phase protector against permanent and transient overvoltages, tripping any shunt release. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8704 - ATCONTROL/B PT-M

ATCONTROL/B PT-M - Single-phase protector against permanent and transient overvoltages, tripping any shunt release. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-8705 - ATCONTROL/D P-T

ATCONTROL/D P-T - Three-phase protector against permanent and transient overvoltages, tripping the residual current breaker. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8706 - ATCONTROL/D PT-T

ATCONTROL/D PT-T - Three-phase protector against permanent and transient overvoltages, tripping the residual current breaker. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8707 - ATCONTROL/D P-M

ATCONTROL/D P-M - Single-phase protector against permanent and transient overvoltages, tripping the residual current breaker. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8708 - ATCONTROL/D PT-M

ATCONTROL/D PT-M - Single-phase protector against permanent and transient overvoltages, tripping the residual current breaker. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-8711 - KIT ATCONTROL/B PT-M 25

KIT ATCONTROL/B PT-M 25 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 25A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8712 - KIT ATCONTROL/B PT-M 32

KIT ATCONTROL/B PT-M 32 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 32A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8713 - KIT ATCONTROL/B PT-M 40

KIT ATCONTROL/B PT-M 40 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 40A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8714 - KIT ATCONTROL/B PT-M 50

KIT ATCONTROL/B PT-M 50 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 50A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8715 - KIT ATCONTROL/B PT-M 63

KIT ATCONTROL/B PT-M 63 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 63A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8716 - KIT ATCONTROL/B PT-T 25

KIT ATCONTROL/B PT-T 25 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 25A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8717 - KIT ATCONTROL/B PT-T 32

KIT ATCONTROL/B PT-T 32 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 32A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8718 - KIT ATCONTROL/B PT-T 40

KIT ATCONTROL/B PT-T 40 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 40A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8719 - KIT ATCONTROL/B PT-T 50

KIT ATCONTROL/B PT-T 50 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 50A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8720 - KIT ATCONTROL/B PT-T 63

KIT ATCONTROL/B PT-T 63 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 63A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8723 - KIT ATCONTROL/B PT-M 6

KIT ATCONTROL/B PT-M 6 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 6A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8724 - KIT ATCONTROL/B PT-M 10

KIT ATCONTROL/B PT-M 10 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 10A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8725 - KIT ATCONTROL/B PT-M 16

KIT ATCONTROL/B PT-M 16 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 16A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8726 - KIT ATCONTROL/B PT-M 20

KIT ATCONTROL/B PT-M 20 - Kit with Single-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 20A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,1kV.

AT-8727 - KIT ATCONTROL/B PT-T 6

KIT ATCONTROL/B PT-T 6 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 6A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8728 - KIT ATCONTROL/B PT-T 10

KIT ATCONTROL/B PT-T 10 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 10A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8729 - KIT ATCONTROL/B PT-T 16

KIT ATCONTROL/B PT-T 16 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 16A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8730 - KIT ATCONTROL/B PT-T 20

KIT ATCONTROL/B PT-T 20 - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current In = 20A. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8750 - KIT ATCONTROL/R P-M 20

KIT ATCONTROL/R P-M 20 - Kit with Single-phase protector against permanent and transient overvoltages, with self-reclosing and 20A contactor. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8751 - KIT ATCONTROL/R P-M 63

KIT ATCONTROL/R P-M 63 - Kit with Single-phase protector against permanent and transient overvoltages, with self-reclosing and 63A contactor. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8752 - KIT ATCONTROL/R P-T 25

KIT ATCONTROL/R P-T 25 - Kit with Three-phase protector against permanent and transient overvoltages, with self-reclosing and 25A contactor. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8753 - KIT ATCONTROL/R P-T 63

KIT ATCONTROL/R P-T 63 - Kit with Three-phase protector against permanent and transient overvoltages, with self-reclosing and 63A contactor. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8754 - KIT ATCONTROL/R PT-T 25

KIT ATCONTROL/R PT-T 25 - Kit with Three-phase protector against permanent and transient overvoltages, with self-reclosing and 25A contactor. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax = 40kA. Up = 1,4kV.

AT-8755 - KIT ATCONTROL/R PT-T 63

KIT ATCONTROL/R PT-T 63 - Kit with Three-phase protector against permanent and transient overvoltages, with self-reclosing and 63A contactor. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax = 40kA. Up = 1,4kV.

AT-8756 - KIT ATCONTROL/R PT-M 20

KIT ATCONTROL/R PT-M 20 - Kit with Single-phase protector against permanent and transient overvoltages, with self-reclosing and 20A contactor. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax = 15kA. Up = 1,5kV.

AT-8757 - KIT ATCONTROL/R PT-M 63

KIT ATCONTROL/R PT-M 63 - Kit with Single-phase protector against permanent and transient overvoltages, with self-reclosing and 63A contactor. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax=15kA. Up = 1,5kV.

AT-8758 - ATCONTROL/R PT-M

ATCONTROL/R PT-M - Single-phase protector against permanent and transient overvoltages, with self-reclosing, tripping any conductor. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-8759 - ATCONTROL/R P-M

ATCONTROL/R P-M - Single-phase protector against permanent and transient overvoltages, with self-reclosing, tripping any conductor. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8760 - ATCONTROL/R P-T

ATCONTROL/R P-T - Three-phase protector against permanent and transient overvoltages, with self-reclosing, tripping any conductor. Actuating time 275V→3-5s / 400V→0,1-0,2s.

AT-8761 - ATCONTROL/B P-T PLUS

ATCONTROL/B P-T PLUS- Three-phase protector against permanent and transient overvoltages and undervoltages, tripping any shunt release. Actuating time 275V→3-5s / 400V→0,1-0,2s / 200V→3-5s / 80V→0,2s.

AT-8762 - ATCONTROL/B PT-T PLUS

ATCONTROL/B PT-T PLUS- Three-phase protector against permanent and transient overvoltages and undervoltages, tripping any shunt release. Actuating time 275V→3-5s / 400V→0,1-0,2s / 200V→3-5s / 80V→0,2s. Imax = 40kA. Up = 1,8kV.

AT-8770 - ATCONTROL/R PT-T

ATCONTROL/R PT-T - Three-phase protector against permanent and transient overvoltages, with self-reclosing, tripping any conductor. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,5kV.

AT-8776 - KIT ATCONTROL/B PT-T 25 PLUS

KIT ATCONTROL/B PT-T 25 PLUS - Kit with three-phase protector against permanent and transient overvoltages and undervoltages, shunt release and MCB with nominal current 25A. Actuating time 275V→3-5s/ 400V→0,1-0,2s. 200V→3-5s/ 80V→0,1-0,2s. Imax=15kA.

AT-8777 - KIT ATCONTROL/B PT-T 32 PLUS

KIT ATCONTROL/B PT-T 32 PLUS - Kit with three-phase protector against permanent and transient overvoltages and undervoltages, shunt release and MCB with nominal current 32A. Actuating time 275V→3-5s/ 400V→0,1-0,2s. 200V→3-5s/ 80V→0,1-0,2s. Imax=15kA.

AT-8778 - KIT ATCONTROL/B PT-T 40 PLUS

KIT ATCONTROL/B PT-T 40 PLUS - Kit with three-phase protector against permanent and transient overvoltages and undervoltages, shunt release and MCB with nominal current 40A. Actuating time 275V→3-5s/ 400V→0,1-0,2s. 200V→3-5s/ 80V→0,1-0,2s. Imax=15kA.

AT-8779 - KIT ATCONTROL/B PT-T 50 PLUS

KIT ATCONTROL/B PT-T 50 PLUS - Kit with three-phase protector against permanent and transient overvoltages and undervoltages, shunt release and MCB with nominal current 50A. Actuating time 275V→3-5s/ 400V→0,1-0,2s. 200V→3-5s/ 80V→0,1-0,2s. Imax=15kA.

AT-8780 - KIT ATCONTROL/B PT-T 63 PLUS

KIT ATCONTROL/B PT-T 63 PLUS - Kit with three-phase protector against permanent and transient overvoltages and undervoltages, shunt release and MCB with nominal current 63A. Actuating time 275V→3-5s/ 400V→0,1-0,2s. 200V→3-5s/ 80V→0,1-0,2s. Imax=15kA.

AT-8796 - KIT ATCONTROL/B PT-T 63 D

KIT ATCONTROL/B PT-T 63 D - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current 63A, Curve D. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8797 - KIT ATCONTROL/B PT-T 80 D

KIT ATCONTROL/B PT-T 80 D - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current 80A, Curve D. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8798 - KIT ATCONTROL/B PT-T 100 D

KIT ATCONTROL/B PT-T 100 D - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current 100A, Curve D. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8799 - KIT ATCONTROL/B PT-T 125 D

KIT ATCONTROL/B PT-T 125 D - Kit with three-phase protector against permanent and transient overvoltages, shunt release and MCB with nominal current 125A, Curve D. Actuating time 275V→3-5s / 400V→0,1-0,2s. Imax(8/20) = 40kA. Up = 1,8kV.

AT-8901 - ATPV

ATPV - Surge protection box for the inverter input at photovoltaic installations. Imax(8/20) = 40kA. Up = 4kV. Uc = 1000Vdc.

AT-8920 - ATPV1000

ATPV1000 - Surge protection box for the inverter input at photovoltaic installations. Imax(8/20) = 75kA. Up = 4kV. Uc = 1000Vdc.

AT-8921 - ATPV1500

ATPV1500 - Surge protection box for the inverter input at photovoltaic installations. Imax(8/20) = 75kA. Up = 5kV. Uc = 1500Vdc.

AT-8923 - ATPV1500T1

ATPV1500T1 - Type 1+2 surge protection box for the inverter input at photovoltaic installations. Imax(8/20) = 40kA. Up = 5kV. Uc = 1500Vdc.

AT-8951 - IGA TEST COMPACT M 16

IGA TEST COMPACT M 16 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 16A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-8952 - IGA TEST COMPACT M 10

IGA TEST COMPACT M 10 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 10A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-8954 - IGA TEST COMPACT M 6

IGA TEST COMPACT M 6 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 6A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-9000 - IGA TEST M 10

IGA TEST M 10 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 10A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9001 - IGA TEST M 25

IGA TEST M 25 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 25A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9002 - IGA TEST M 32

IGA TEST M 32 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 32A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9003 - IGA TEST M 40

IGA TEST M 40 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 40A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9004 - IGA TEST M 50

IGA TEST M 50 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 50A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9005 - IGA TEST M 63

IGA TEST M 63 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 63A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9006 - IGA TEST T 25

IGA TEST T 25 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 25A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9007 - IGA TEST T 32

IGA TEST T 32 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 32A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9008 - IGA TEST T 40

IGA TEST T 40 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 40A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9009 - IGA TEST T 50

IGA TEST T 50 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 50A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9010 - IGA TEST T 63

IGA TEST T 63 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 63A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9031 - IGA TEST M 25 PLUS

IGA TEST M 25 PLUS - Single-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 25A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9032 - IGA TEST M 32 PLUS

IGA TEST M 32 PLUS - Single-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 32A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9033 - IGA TEST M 40 PLUS

IGA TEST M 40 PLUS - Single-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 40A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9034 - IGA TEST M 50 PLUS

IGA TEST M 50 PLUS - Single-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 50A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9035 - IGA TEST M 63 PLUS

IGA TEST M 63 PLUS - Single-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 63A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9036 - IGA TEST T 25 PLUS

IGA TEST T 25 PLUS - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 25A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9037 - IGA TEST T 32 PLUS

IGA TEST T 32 PLUS - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 32A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9038 - IGA TEST T 40 PLUS

IGA TEST T 40 PLUS - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 40A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9039 - IGA TEST T 50 PLUS

IGA TEST T 50 PLUS - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 50A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9040 - IGA TEST T 63 PLUS

IGA TEST T 63 PLUS - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 63A. Actuating time 275V -> 8-10s / 400V -> 0,1-0,2s: 80V -> 0,2s / 200V -> 0,8s.

AT-9052 - IGA TEST M 6

IGA TEST M 6 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 6A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9053 - IGA TEST M 16

IGA TEST M 16 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 16A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9054 - IGA TEST M 20

IGA TEST M 20 - Single-phase protector against permanent, overvoltages, with integrated MCB, nominal current 20A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9055 - IGA TEST T 6

IGA TEST T 6 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 6A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9056 - IGA TEST T 10

IGA TEST T 10 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 10A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9057 - IGA TEST T 16

IGA TEST T 16 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 16A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9058 - IGA TEST T 20

IGA TEST T 20 - Three-phase protector against permanent, overvoltages, with integrated MCB, nominal current 20A. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9070 - IGA TEST COMPACT M 20

IGA TEST COMPACT M 20 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 20A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-9071 - IGA TEST COMPACT M 25

IGA TEST COMPACT M 25 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 25A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-9072 - IGA TEST COMPACT M 32

IGA TEST COMPACT M 32 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 32A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-9073 - IGA TEST COMPACT M 40

IGA TEST COMPACT M 40 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 40A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-9074 - IGA TEST COMPACT M 50

IGA TEST COMPACT M 50 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 50A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-9075 - IGA TEST COMPACT M 63

IGA TEST COMPACT M 63 - Single-phase protector against permanent and transient overvoltages, with integrated MCB, nominal current 63A. Actuating time 275V→8-10s / 400V→ 0,1-0,2s. Imax(8/20) = 15kA. Up = 1,5kV.

AT-9076 - IGA TEST T 63 D

IGA TEST T 63 D - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 63A, D curve. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9077 - IGA TEST T 80 D

IGA TEST T 80 D - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 80A, D curve. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9078 - IGA TEST T 100 D

IGA TEST T 100 D - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 100A, D curve. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9079 - IGA TEST T 125 D

IGA TEST T 125 D - Three-phase protector against permanent overvoltages and undervoltages, with integrated MCB, nominal current 125A, D curve. Actuating time 275V→8-10s / 400V→0,1-0,2s.

AT-9101 - ATFONO

ATFONO - Surge protection for 2 pairs of analogical or ADSL telephone lines. In(C2) = 2/8kA. Up = 270V. Uc = 220V.

AT-9104 - ATFONO RJ11

ATFONO RJ11 - Protection for analogical or ADSL telephone lines with RJ11 connector. C2 test (2kA/4KV). Up = 330V. Uc = 270V. Includes 20 cm cable for connection.

AT-9105 - ATFONO R&M1

ATFONO R&M1 - Surge protection for analogical or ADSL telephone lines with Reichle & De-Massari connections. In(C2) = 5kA. Up = 400V.

AT-9106 - ATFONO R&M2

ATFONO R&M2 - Surge protection for analogical or ADSL telephone lines with Reichle & De-Massari connections. In(C2) = 0,1kA. Up = 400V.

AT-9107 - ATFONO Mod.

ATFONO Mod. - Pluggable module for surge protection of power lines. Un = 130VDC. In = 2kA. Up = 270V.

AT-9108 - ATFONO RJ45

ATFONO RJ45 - Surge protection for analogical or ADSL telephone lines with RJ45 connector. C2 test (2kA/4KV). Up = 270V. Uc = 220V. Includes 50cm cable for connection.

AT-9109 - ATFONO KRONE

ATFONO KRONE - Surge protection for analogical or ADSL telephone lines with KRONE connections. In(C2) = 5kA. Up = 300V.

AT-9205 - ATLINE 5

ATLINE 5 - SPD for the protection of DC lines with Un = 5VDC. C2 Test (2kA/4kV). Up = 66 V.

AT-9206 - ATLINE 5 Mod.

ATLINE 5 Mod. - Pluggable module for surge protectors of DC lines with Un = 5VDC. In = 5kA. Up = 66 V.

AT-9210 - ATLINE 110

ATLINE 110 - SPD for the protection of DC lines with Un = 110VDC. C2 Test (2kA/4kV). Up = 160 V.

AT-9211 - ATLINE 110 Mod .

ATLINE 110 Mod. - Pluggable module for surge protectors of DC lines with Un = 110VDC. In = 2kA. Up = 160 V.

AT-9212 - ATLINE 12

ATLINE 12 - SPD for the protection of DC lines with Un = 12VDC. C2 Test (2kA/4kV). Up = 66 V.

AT-9213 - ATLINE 12 Mod.

ATLINE 12 Mod. - Pluggable module for surge protectors of DC lines with Un = 12VDC. In = 5kA. Up = 66 V.

AT-9215 - ATLINE 15

ATLINE 15 - SPD for the protection of DC lines with Un = 15VDC. C2 Test (2kA/4kV). Up = 66 V.

AT-9216 - ATLINE 15 Mod.

ATLINE 15 Mod. - Pluggable module for surge protectors of DC lines with Un = 15VDC. In = 5kA. Up = 66 V.

AT-9224 - ATLINE 24

ATLINE 24 - SPD for the protection of DC lines with Un = 24VDC. C2 Test (2kA/4kV). Up = 70 V.

AT-9225 - ATLINE 24 Mod.

ATLINE 24 Mod. - Pluggable module for surge protectors of DC lines with Un = 24VDC. In = 5kA. Up = 70 V.

AT-9230 - ATLINE 30

ATLINE 30 - SPD for the protection of DC lines with Un = 30VDC. C2 Test (2kA/4kV). Up = 70 V.

AT-9231 - ATLINE 30 Mod.

ATLINE 30 Mod. - Pluggable module for surge protectors of DC lines with Un = 30VDC. In = 5kA. Up = 70 V.

AT-9248 - ATLINE 48

ATLINE 48 - SPD for the protection of DC lines with Un = 48VDC. C2 Test (2kA/4kV). Up = 100 V.

AT-9249 - ATLINE 48 Mod.

ATLINE 48 Mod. - Pluggable module for surge protectors of DC lines with Un = 48VDC. In = 5kA. Up = 100 V.

AT-9260 - ATLINE 60

ATLINE 60 - SPD for the protection of DC lines with Un = 60VDC. C2 Test (2kA/4kV). Up = 120 V.

AT-9261 - ATLINE 60 Mod.

ATLINE 60 Mod. - Pluggable module for surge protectors of DC lines with Un = 60VDC. In = 5kA. Up = 120 V.

AT-9280 - ATLINE 80

ATLINE 80 - SPD for the protection of DC lines with Un = 80VDC. C2 Test (2kA/4kV). Up = 140 V.

AT-9281 - ATLINE 80 Mod.

ATLINE 80 Mod. - Pluggable module for surge protectors of DC lines with Un = 80VDC. In = 2kA. Up = 140 V.

AT-9320 - ATCOMBO 12

ATCOMBO 12 - Surge protector for 12VDC lines with Schuko connector in a watertight proof box. In = 10kA. Up = 570V.

AT-9325 - ATCOMBO 24

ATCOMBO 24 - Surge protector for 24VDC lines with Schuko connector in a watertight proof box. In = 10kA. Up = 630V.

AT-9326 - ATCOMBO 48

ATCOMBO 48 - Surge protector for 48VDC lines with Schuko connector in a watertight proof box. In = 10kA. Up = 630V.

AT-9450 - IGA TEST SUB M1 20

IGA TEST SUB M1 20 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9451 - IGA TEST SUB M1 25

IGA TEST SUB M1 25 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9452 - IGA TEST SUB M1 32

IGA TEST SUB M1 32 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9453 - IGA TEST SUB M1 40

IGA TEST SUB M1 40 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9454 - IGA TEST SUB M1 50

IGA TEST SUB M1 50 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9455 - IGA TEST SUB M1 63

IGA TEST SUB M1 63 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9456 - IGA TEST SUB T1 20

IGA TEST SUB T1 20 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9457 - IGA TEST SUB T1 25

IGA TEST SUB T1 25 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9458 - IGA TEST SUB T1 32

IGA TEST SUB T1 32 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9459 - IGA TEST SUB T1 40

IGA TEST SUB T1 40 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9460 - IGA TEST SUB T1 50

IGA TEST SUB T1 50 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9461 - IGA TEST SUB T1 63

IGA TEST SUB T1 63 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9462 - IGA TEST SUB T1 80

IGA TEST SUB T1 80 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9463 - IGA TEST SUB T1 100

IGA TEST SUB T1 100 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9464 - IGA TEST SUB T1 125

IGA TEST SUB T1 125 - Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

AT-9501 - ATSOCKET

ATSOCKET: Indoors protector for power supply lines to be installed inside the cable channels that feed the sockets. In = 3kA. Up = 800V.

AT-9505 - ATSOCKET 5kA

ATSOCKET 5kA - Surge protector for LED street lighting. Uc = 400Vac. In = 5 kA. Up = 1400V. Includes disconnecting thermal fuse.

AT-9601 - ATPLUG

ATPLUG: Single phase line protection for Schuko plug. In = 3kA. Up = 800V.

AT-9602 - ATPLUG 130V

ATPLUG: Single phase line protection for type B NEMA 5 plug. Un = 130V. In=3kA. Up=800V.

AT-9608 - ATPLUG CONTROL

ATPLUG CONTROL - Single-phase self-reclosing protector against permanent and transient overvoltages and undervoltages. With Schuko type plug. In = 3kA. Up = 800V.

AT-9609 - ATPLUG CONTROL 120 V

ATPLUG CONTROL 120 V - Single-phase self-reclosing protector against permanent and transient overvoltages and undervoltages. With NEMA 5-15P type plug. In = 3kA. Up = 800V.

ATBARRIER

Coordinated protection cabinets for power supply lines.

ATCOMBO

Protection of power supply lines with Schuko base.

ATCOMPACT CDA

Multi-pole power supply protection cabinet including protective fuses.

ATCONTROL/B

Self-configurable permanent and transient overvoltage protector.

ATCONTROL/B PLUS

Self-configurable permanent and transient overvoltage and undervoltage protector.

ATCONTROL/D

Self-configurable permanent and transient overvoltage protector actuating on a 30 mA residual current breaker.

ATCONTROL/R

Self-configurable self-reclosing permanent and transient overvoltage protector for power supply lines.

ATCOVER

Compact protector for three-phase power supply lines in common and differential mode.

ATCOVER M

Compact protector for single-phase power supply lines in common and differential mode.

ATCOVER TNC

Compact protector for TNC and IT three-phase power supply lines in common and differential mode.

ATDB9

Individual overvoltage protector for type DB9 data lines.

ATFONO

Modular protector against overvoltages for telephone lines for DIN rail.

ATFONO KRONE / R&M

Protector for telephone lines for KRONE or Reichle & De-Massari connections with earthing terminal.

ATFONO RJ11

Protector for telephone lines with RJ11 connection

ATFONO RJ45

Protector for telephone lines with RJ11 connection.

ATFREQ

Overvoltage protection devices for coaxial cables.

ATLAN-C 8

Protector against overvoltages for 8 computer lines in one box.

ATLAN

Individual protector for computer networks.

ATLINE

Modular overvoltage protector for data lines for DIN rail.

ATLINK

Decoupling inductor for protector power supply coordination.

ATLOGGER

ATLOGGER is a recorder of electrical activity in the lightning rod's downconductor which, in addition to counting the number of strikes, records the amplitude and polarity of the lightning, as well as the date and time the impact occurred.

ATPLUG

Electrical plug-in protector.

ATPLUG CONTROL

Plug-in self-reclosing permanent and transient overvoltage and undervoltage protector.

ATPV

Protection for photovoltaic installations.

ATSHIELD

Combined technology against direct lightning strikes.

ATSHIELD M

Combined technology against direct lightning strikes.

ATSHIELD S

Combined technology against direct lightning strikes.

ATSHIELD T

Combined technology against direct lightning strikes.

ATSHIELD TT

Combined technology against direct lightning strikes.

ATSHOCK-P 30

Single-pole and removable plug protection for power supply lines.

ATSHOCK

Maximum single-pole protection for power supply lines.

ATSHOCK 25

Single-pole and pluggable protection for power supply lines.

ATSHOCK 30

Single-pole protection for power supply lines.

ATSOCKET

Indoor protector for power supply lines.

ATSUB-2P-NR TT

Compact protection for TT single-phase power supply lines.

ATSUB-2P TN

Compact protection for TN single-phase power supply lines.

ATSUB-2P TT

Compact protection for TT single-phase power supply lines.

ATSUB-3P-NR

Compact protection for two-phase power supply lines with neutral for american voltages.

ATSUB-3P TNC

Compact protector for TNC three-phase power supply lines.

ATSUB-4P-NR TT

Compact protection for TT three-phase power supply lines.

ATSUB-4P TNS

Compact protection for TNS three-phase power supply lines.

ATSUB-4P TT

Compact protection for TT three-phase power supply lines.

ATSUB-D M

Compact single-phase protection for domestic use.

ATSUB-P

Single-pole and pluggable protection for power supply lines.

ATSUB-PR

Single-pole and pluggable protection for power supply lines.

ATSUB-R

Single-pole protection for power supply lines.

ATSUB

Single-pole protection for power supply lines.

ATSUB 100

Single-pole and pluggable protection for power supply lines.

ATSUB 140

Single-pole and pluggable protection for power supply lines.

ATVOLT

Coordinated direct current power supply for overvoltage protection devices.

Adapting piece

Suitable for fixing the lightning rod in the mast with internal conductor (tape, cable or round) connection.

Adjustable anchorage

Due to the covers or cornices of the roofs, a substantial horizontal distance needs to be avoided. In these cases it is necessary to use the extendible tube (60 to 80 cm).The anchorages require a minimum of 60 cm between each other in order to ensure they are correctly fixed.

Adjustable tile anchorage

Used for supporting Franklin air termination rods onto the roof tiles without them becoming damaged. This anchorage adjusts to different sizes and inclinations of tiles.

Air rod base

Used for supporting lightning conductor air terminals on the flat roof and connecting to the tape.

Aluminium tape conductors

Aluminium tape is easier to install than copper tape but has lower conductivity. Not suitable for direct contact with the soil.

Angle bar anchorage

1” - 1½” mast anchorage to be welded to metal structures. The anchorages require a minimum of 60 cm between each other in order to ensure they are correctly.

Anti-corrosion spray

This cold galvanizer spray protects all kind of metals from corrosion. Specially used to protect welding.

B bond

This connection bonds the copper or aluminium tapes with the metal structures. The screw size is M10.

Back plate holdfast

Used when the installation requires the conductor to be fixed at a certain distance from the surface.Plug and screw included.

Bare solid round

Solid round conductors are more suitable for corrosive environments.

Basic accessories kit

Basic set of accessories for Apliweld: cleaning brush for conductors, slag removal spade, mould brush, cavity cleaning brush, sealer compound and safety gloves. The AT-068N tool set includes a spark lighter for traditional starting powder ignition.

Bimetallic connector

Used for bonding copper, aluminium or galvanized steel conductors, preventing galvanic coupling, particularly where an aluminium or galvanized steel lightning protection system has to be connected to a copper earthing system.

Bonding bars for earth pits

They enable the down-conductor of the lightning protection system to disconnect from the earth electrode in order to correctly measure the earth resistance.

CONDUCTIVER PLUS

CONDUCTIVER PLUS is a ground enhancing gel with low solubility which is, nonetheless, very hygroscopic. It is made of an electrolyte base, which contributes to the conductivity of the mixture.

Clamping frame

Used for fixing down-conductors (round conductor or cable) to metal structures. Include M8 x 30 mm bolt.

Concrete base

Used to fix air termination rods to flat roofs. These bases are not recommended for use with airrods over 3 m high due to wind load. AT-029B only allows Ø10 x 1000 mm and Ø16 x 1000 mm air termination

Conical rod holder

Rod holder for flat roofs where it is not possible to drill in order to secure the rod, such as bitumen roofs. Supplied empty to be then filled with concrete. The lip at the bottom of the cone allows it to be embedded in concrete or bitumen. It can also be sealed with polymer.

Conical roof conductor holder

Conductor holder for flat roofs where it is not possible to drill in order to secure the conductor, such as bitumen roofs. The lip at the bottom of the cone allows it to be embedded in concrete or bitumen. It can also be sealed with polymer.

Connecting clamp

Cross-shape earth clamp for connection between cable, round bar or tape and earth rod.

Copper-clad aluminium bimetal conductor

Copper-clad aluminium conductors (Cu 15%) maintain the electrical characteristics of copper conductors but with a lower cost. Installation with this material is easier than using copper-steel due to its high malleability.

Copper-steel bimetal conductor

Copper-steel conductors (Cu 25%) maintain the electrical characteristics of the electrolytic copper, along with the best mechanical properties of steel.

Copper lattices and grids

Mesh earthing systems are a more cost-effective option than earth plates and still work well in stony ground, reducing the step or contact voltages that may occur.

Cover plate

To be used in conjunction with any screw threaded attachments in order to protect it

Cross shaped anchorage

Cross-shape double bracket anchoring system, for fixing 1” - 1 ½”mast to horizontal sections of handrail or piping. The anchorages require a minimum of 60 cm between each other, and a robust structure, in order to ensure they are correctly fixed.

DAT CONTROLER® PLUS

DAT CONTROLER® PLUS is an Early Streamer Emission (ESE) air terminal based on the electrical characteristics of lightning formation. The air terminal triggers the continuous upward leader before any other object within its radius of protection. DAT CONTROLER® PLUS terminals offer the highest performance guarantees.

DAT CONTROLER® REMOTE

DAT CONTROLER® REMOTE is an Early Streamer Emission (ESE) air terminal based on the electrical characteristics of lightning formation. The air terminal triggers the continuous upward leader before any other object within its radius of protection. DAT CONTROLER® REMOTE terminals offer the highest performance guarantees. Furthermore, they are provided with daily remote verification, with available data in real time at a web app using 2G/3G network. M2M communication and web portal for daily information on status of air terminals.

DC tape clip

Suitable for fixing the tape conductor to the building. Plug and screw included.

Distance holder

Allows the use of galvanized steel tape as a ground conductor at foundation level.

Downpipe cable holder

Adjustable rainwater pipe conductor holder, for Ø8 mm round conductor or 50 mm2 cable.

Downpipe clamp

50 -120 mm rainwater pipe clamp, for Ø6 - 10 mm round conductor or 25 - 70 mm2 cable.

Earth bars

Equipotential bars enable connection of various cables or round conductors with tin-plated copper connection terminals (for instance, AT- 021K) carried out using 50 x 5 mm tape.

Earth boss

Earth boss for metal structure. M10 thread

Earth pits

Aplicaciones Tecnológicas earth pits cover all industrial and commercial applications as they are available in 3 materials: polypropylene, concrete and cast iron.

Earth plates

The use of earth plates as electrodes significantly reduces the resistance of earthing in stony grounds, as it increases the area of contact between the electrode and the ground.

Earth point

Equipotential earth points which are fixed to the structure to provide attachment points for the earthing conductors.

Earthing pipe clamp

Rainwater support with clamp to connect to earthing system or to fix the down-conductor.

Equipotential bonding bar

Equipotential bar enabling several conductors to be connected to each other (cable, tape, round bar). The attachment holes at the end of the bar are separated by 164 x 35 mm and have a diameter of 8.5 mm.

Extension

Used when the installation requires the conductor to be fixed at a certain distance from the surface. Plug and screw included.

Fixed earthing terminal

Terminal which is attached to the structur e to provide accessible earth point. M10 thr ead.

Flat saddle

Used for supporting lightning conductor air terminals on the flat roof and connecting to the cable or round.

Flexible braid bond

This flexible braid allows an equipotential bond between diverse metal elements such as fences, doors and windows. Fixed using Ø11 mm holes.

Free standing mast

Self supporting mast with polygonal section measured for wind velocity up to 250 Km/h. Ø1½” at the top. They are made of pyramidal trunk sections that slot into each other so the sections do not need to be joined by stud-bolts or welding and the hinge means they can be raised using a small crane. It is possible to install a lightning strike counter AT-034G inside the mast behind the inspection hatch in the base.

Galvanized steel earth rods

Galvanized steel earth rods are a good option to obtain a good earth resistance in unaggressive ground. There are extendible models to reach longer lengths and achieve better earth resistance.

General clamp type G

Accessory to facilitate safe fastening, closing and handling of the moulds it is to be used with. Bigger clamp, valid for large conductors and some particular welds such as LO, XO,TO types.

General clamp type S

Accessory to facilitate safe fastening, closing and handling of the moulds it is to be used with. This is the most common clamp, suitable for approximately 80% of connections.

Goose foot

The goose foot is a configuration recommended by lightning protection standards UNE 21186 and NF C 17-102 in order to obtain low inductance in the earthing system. It consists of 30 x 2 mm tin-plated copper tape

Graphite electrode

The fact that graphite exhibits high electrical and thermal conductivity and is unassailable and inert to chemical agents, makes it a very suitable element for building an earth electrode. The materials used as filling (graphite powder and thin clay-like powder) ensure contact between the electrode and the ground thanks to its capacity to penetrate even cracks in rocks.

Guard tubes

Anti-vandal guard for cable or tape down-conductors. In order to avoid the cable breaking due to accidental impacts, it is necessary to install a guard tube, which is at least 2 metres high, wherever the cable is accessible. AT-056G is recommended to prevent touch voltages in public buildings with low resistivity soil.

Gutter clamp

Clamp for Ø6-10 mm round conductor to be fixed at the edge of the gutter.

Hanging guy wire kit

For installing guy wire to hold the cable or round conductor over flat traffic-bearing terraces. The cable is joined to the guy wire using AT-046C.

IGA TEST

Compact protector against permanent overvoltages with integrated miniature circuit breaker.

IGA TEST COMPACT

Compact protector against transient and permanent overvoltages with integrated miniature circuit breaker.

IGA TEST D

Permanent overvoltage protector with integrated D curve main circuit breaker.

IGA TEST PLUS

Protector against permanent overvoltages and undervoltages with integrated miniature circuit breaker.

IGA TEST SUB M1

Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

IGA TEST SUB M

Prewired protector against transient and permanent overvoltages with integrated miniature circuit breaker.

IGA TEST SUB T1

Type 1 protector against transient and permanent overvoltages with integrated miniature circuit breaker.

KIT ATCONTROL/B

Complete kit including self-configurable permanent and transient overvoltage protector, shunt release and circuit breaker.

KIT ATCONTROL/B D

Complete kit including self-configurable permanent and transient overvoltage protector, shunt release and D curve circuit breaker.

KIT ATCONTROL/B PLUS

Complete kit including self-configurable permanent and transient overvoltage and undervoltage protector, shunt release and circuit breaker.

KIT ATCONTROL/R

Self-configurable self-reclosing permanent and transient overvoltage protector for power supply lines.

KS cable clip

For connecting round conductor or cable to flat profiles.

Kit APLIWELD®-E

Traditionally, once the conductors were inserted in the graphite mould, the welding compound and the reactive powder (usually a flammable compound) were poured into the crucible. Then a flint gun, applied manually to the starting powder at arm’s length produced a spark triggering the exothermic reaction. With APLIWELD® -E, the electronic starter is inserted on top and activated from a distance. Hence it is completely safe for the operator.

Lamppost anchorage

1” - 1½” mast anchorage fixture adjustable for conic structures such as lamp posts.The anchorages require a minimum of 60 cm between each other in order to ensure they are correctly fixed.

Light anchorage

1” - 1½” mast anchorage to be embedded or screwed into the wall. The anchorages need a minimum of 60 cm between each other and at least 30 cm from the top of the wall in order to ensure correct attachment.

Light bracket

Down-conductor clip for fixing 30 x 2 mm or 30 x 3.5 mm tape to flat surface. Using AT-050E with bare copper tape may cause galvanic coupling. Plug and screw included.

Lightning event counter

The AT-034G lightning event counter is a device to be installed on the down-conductor, usually above the guard tube. It automatically counts the strikes received by the lightning protection system. It is very sturdy and totally autonomous, however it is advisable to check it periodically in order to see if there has been a strike and, therefore, whether or not the lightning protection system needs any special maintenance. This counter is designed to be installed inside self-supporting masts and interrupting the downconductor is not necessary for its installation.

Mast anchorage for flat roof

1 ½” mast support for flat roofs which can be drilled. If not, a concrete base will be required. 70 x 70 x 25 cm concrete base is recommended in order to avoid any damage to the roof.

Mast to post anchorage

Suitable for fixing a 1” - 1½” mast to a 25 cm square or round post. The anchorages require a minimum of 60 cm between each other in order to ensure they are correctly fixed.

Mast to trestle tower anchorage

1” - 1½” mast anchorage to be fixed to trestle towers. Not recommended for masts higher than 6 m. The anchorages require a minimum of 60 cm between each other in order to ensure they are correctly fixed.

Masts for wall or structural fixing

Elevation up to 8 m. For attachment using 2 anchorage supports, except those which are 8 m high, in which case 3 anchorage supports are needed. The distance between supports must be 60 cm. In atmospheres with a high level of corrosion, the use of stainless steel masts is recommended.

Metal fixation

Component for fixing cable or tape clips onto metal surfaces.

Metal sheet clamp

EEquipotential bond between round, cable or tape and metal sheet.quipotential bonds for round conductor and cable.

Metallic support

These supports are fixed using screws or adhesive to flat surfaces or welded onto metal structures. Suitable for use with rods such as AT-053L.

Metallic tape clip

Down-conductor support clip for 30 x 2 or 30 x 3.5 mm tape to flat surfaces.

Multi-point

Multi-point with naval brass adapting piece. Suitable for use with mast 1½”.

Multiple mold

The multiple mould is a system designed to make different connections using the same graphite pieces. Multiple mould is focused for horizontal T, cross and earth rod welding. However, in some cases it can also weld straight and parallel bonds. The multiple mould is the best solution if only a few common welding types are required, when the features of the work to be carried out cannot be predicted, when conductor sizes are variable or in case of any unexpected occurrences during installation.

Multipurpose clamp

Earth clamp for connection between cable, round bar or copper tape and copper or copperbond earth rods.

Naval brass cable clip

Down-conductor clip for fixing round conductor or cable to flat surface. AT-011E suitable to use on corners. The AT-009E includes screws and washers suitable for metal sheets or sandwich panels. AT-262E includes self-drill double screw and neoprene washer for metal structures. AT-013E and AT-014E are designed to avoid obstacles such as cornices.

Nylon cable clip ø13 - 16 mm

Nylon clip to secure round conductor or cable. Also suitable for securing air termination rods to the side of the building.

One hole cable clip

Simple holder to secure cable or round conductor to the wall. Plug and screw included.

Other clamps and accessories

Other accessories are required for less common connections or to ensure good quality welding according to working conditions.

PVC covered solid round

Solid round conductors coated in PVC are used to blend the down-conductor into the building.

Parallel anchorage

Double bracket anchoring system for fixing 1” - 1½” mast in parallel to vertical sections of handrail or piping. The anchorages require a minimum of 60 cm between each other, and a robust structure, in order to ensure they are correctly fixed.

Parallel clamp

Parallel bond for cable or round conductor. AT-013F is used for bonds between copper and aluminium conductors, preventing galvanic coupling.

Pipe bond

Used to fix an 8 mm diameter down-conductor to large diameter piping.

Push-in tape clip

Hold-fast clip to secure the tape conductor to a flat surface. Plug and screw included.

Rainwater pipe (RWP) bond

This bonds copper or aluminium tapes to metal circular surfaces such as rainwater pipes, handrails, etc. The bolt size is M10.

Reduced anchorage

Used for supporting Ø10 mm taper pointed air rods on the roof and connecting to the cable or round. They are not recommended for use in combination with the 1 m taper pointed air rods.

Ridge anchorage

Anchorage for 16 to 34 mm air rods to be screwed into the wall. The anchorages need a minimum of 50 cm between each other and at least 20 cm fromthe top of the wall in order to ensure correct attachment. Clip included for Ø6-10 mmconductor.

Ridge saddle

Used for supporting lightning conductor air terminals on the ridge of the roof and connecting to the tape.

Rod bracket

This unit screws onto the air rod and connects to the tape by means of the screws provided.

Rod to cable CGUV clamp

Earth clamp for connection between copper cable or round bar and earth rods or metal re-bars.

Rod to cable coupling

These brackets are mainly used where it is not possible to fit a saddle on the roof.

Rod to cable lug B clamp

Earth clamp for connection between copper cable with copper compression terminal and copper or copperbond earth rods.

Rod to tape A clamp

Earth clamp for connection between copper tape and copper or copperbond earth rods.

Rod to tape coupling

This unit screws onto the air rod and connects to the cable by means of the screws provided.

Sandwich roof support

Corrugated or sandwich roof supports. The support employs existent metal sheet fixings.

Self-supporting air termination rod

Tapered air-terminal rod with hinged tripod support for protection of roof structures that stick out, such air conditioning systems. The air terminal rods are designed for wind speed of up to 145 km/h. The stackable concrete bases, the flat washers and the clip for round conductor Ø6-10 mm. The rod is made of aluminium. The rod is made of aluminium.

Self supported tower

1½” elevation fixture up to 26 m. The total height from ground includes the tower + 6 m mast that is provided.

Solid copper earth rods

Solid copper rods enable long-lasting earthing in ground with high corrosion levels. Threaded electrodes with the correct accessories enable the length to be increased, thus achieving a better earth resistance.

Spark gap for aerial mast

Aerials are particularly exposed to lightning strikes and their consequences. The lightning protection system must protect the aerial against direct impact, however part of the lightning current could side-strike it and follow an uncontrolled path to earth. Even if it is only part of the lightning current, the damage caused could be very significant. The AT-060F protector is connected to the aerial mast in order to ensure an equipotential bond between metal elements, thereby preventing dangerous sparks between the lightning protection system and the aerial mast, which could result in fire and damage to the structure.

Spark gap for earth bonding

In normal conditions, this protector keeps the earth connections isolated, thus avoiding corrosion problems. When a discharge occurs and the voltage increases in the earth connections, the spark gap will activate, directly joining the earth connections and thus preventing current passing from one to another through equipment or internal installations.

Special rod support

For fixing air rods with M10 male or female threads to vertical surfaces or to the top of the aerial mast. The AT-030M is for masts from Ø6 - 50 mm.

Specific moulds

Each mould makes a particular connection: one mould welds two specific conductors (cable to cable, tape to tape, cable to earth rod…), with specific dimensions (50 mm², 70 mm², etc.) and joined in a certain way (cross or T shape etc.). This tool generates a list of the references and quantities of material necessary to make the required connections:

Spring tile support

For fixing the conductor clips to tile. This support has a spring to adapt to tiles ranging from 180 to 280 mm.

Square cable clamp

Linear, T, L and cross-shape equipotential bonds for round conductor and cable.

Stainless steel earth rods

Stainless steel earth rods enable long-lasting earthing in ground with high corrosion levels. Threaded electrodes with the correct accessories enable the length to be increased, thus achieving a better earth resistance.

Strike pad

Equipped with a screw to fix the lightning conductors.

T clamp

T equipotential bonds for round conductor and cable.

Tape buckle clip

Down-conductor holder suitable for fixing 30 x 2 or 30 x 3.5 mm tape to flat surface. The AT-006E and AT-061E include suitable screws and neoprene washers for metal sheets or sandwich panels. AT-012E and AT-019E include self-drill double screws and neoprene washers for metal structures. AT-216E and AT-217E are designed to overcome obstacles such as cornices.

Tape clip

Suitable for securing the tape conductors to a flat surface, using two screws. Plugs and screws included.

Tape test clamp

Specially used for disconnection and test purposes for tape conductors.

Test joint

Disconnecting sleeve between galvanized steel round and tape conductor.

Tile support

For fixing the clip to the tile without causing any damage in such a way that the conductor can be fixed afterwards.

Tinned copper tape conductors

Tin-plated copper tape is recommended for use as a down-conductor and earth conductor in lightning protection systems.

Tower earth clamp

They bond copper cable or round conductor to metal structures. M10 bolts are used for AT-026J and AT-027J. Other references have M12 screws.

Trestle tower

Towers that elevate up to 26.5 m with guy wires included. Ø1½” x 3 m mast is included. Each triangular section measures 180 mm x 3 m. If the flat roof cannot be perforated, a concrete base is needed for the trestle tower and the guy wire anchorages. 3 guy wire must be installed with 120º between them. The trestle towers can also be placed on walls using a trestle tower-wall anchorage. They must be assembled section by section and tightened using guy wires. The 3 guy wire anchorages must be joined to the downconductor at fixation level.

U-bolt rod E clamp

Earth clamp for connection between copper tape and earth rods or metal re-bars.

U shaped anchorage

1” - 1½” mast anchorage to be embedded or screwed into the wall. The 60 cm U-shaped anchorages are designed to avoid obstacles such as cornices of up to 50 cm. The anchorages need a minimum of 60 cm between each other and at least 30 cm from the top of the wall in order to ensure correct attachment.

Universal clamp

Cross or parallel bond between copper cables or round conductors.

Universal clamp

L or cross-shape earth clamp for connection between cable or round bar and earth rod.

Watertight cone

It prevents water penetrating flat roof surfaces. Used with Ø6 to 50 mm air rods and masts.

Wire straightener

For straightening round conductors made of medium-hard materials.