{"id":50164,"date":"2019-09-26T00:00:00","date_gmt":"2019-09-25T22:00:00","guid":{"rendered":"https:\/\/at3w.com\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/"},"modified":"2019-09-26T00:00:00","modified_gmt":"2019-09-25T22:00:00","slug":"aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503","status":"publish","type":"post","link":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/","title":{"rendered":"Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-flat ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#What_are_the_features_of_the_Power_Supply_Tester_of_Aplicaciones_Tecnologicas\" >What are the features of the Power Supply Tester of Aplicaciones Tecnol&oacute;gicas?<\/a><\/li><li class='ez-toc-page-1'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#How_does_the_AT-3503_Power_Supply_Tester_work\" >How does the AT-3503 Power Supply Tester work?<\/a><\/li><li class='ez-toc-page-1'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#How_many_records_can_you_save_in_the_memory\" >How many records can you save in the memory?<\/a><\/li><li class='ez-toc-page-1'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#Technical_Characteristics_of_the_Power_Supply_Tester_AT-3503\" >Technical Characteristics of the Power Supply Tester AT-3503<\/a><\/li><li class='ez-toc-page-1'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#What_type_of_installation_does_it_require\" >What type of installation does it require?<\/a><\/li><\/ul><\/nav><\/div>\n<p>\n\tThe new AT-3503 Power Supply Tester of <a href=\"https:\/\/lightningprotection-at3w.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">Aplicaciones Tecnol&oacute;gicas<\/a> is responsible for monitoring and detecting dangerous voltages, network frequency variations as well as increases in the resistance of the earth loop of an installation. The line tester detects any network anomaly by acting through its dry contact relays.<\/p>\n<p>\n\tThis device also has a screen showing voltages, frequency and impedance in real time. When an alarm sounds the Power Supply Tester AT-3503 indicates it intermittently on the screen and saves the event in your memory for further verification.<\/p>\n<p>\n\tThis is a very useful tool because if the neutral is cut by a permanent power surge or undervoltage the device will inform you. In the same way, in case the ground or neutral cable is disconnected, the tester will detect and indicate it.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_are_the_features_of_the_Power_Supply_Tester_of_Aplicaciones_Tecnologicas\"><\/span>\n\t<strong>What are the features of the Power Supply Tester of Aplicaciones Tecnol&oacute;gicas?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>\n\t\tThe equipment has two dry contact relays which are activated when a voltage and\/or impedance alarm occurs.<\/li>\n<li>\n\t\tCan be connected to a three-phase network, either 120Vac (L-N) or 230Vac (L-N).<\/li>\n<li>\n\t\tIt is self-configurable, which allows it to recognize the type of network it is connected to in the first initiation.<\/li>\n<li>\n\t\tInternal memory is capable of storing up to 50 voltage events and 50 impedance events, which can be viewed by browsing the screen.<\/li>\n<\/ul>\n<p>\n\tIn addition, the thresholds of overvoltages and undervoltages can be configured by the user.<\/p>\n<p>\n\tThe default values are:<\/p>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td>\n<p>\n\t\t\t\t\tType of network<\/p>\n<\/td>\n<td>\n<p>\n\t\t\t\t\tUndervoltage<\/p>\n<\/td>\n<td>\n<p>\n\t\t\t\t\tOvervoltage<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\n\t\t\t\t\t120Vac<\/p>\n<\/td>\n<td>\n<p>\n\t\t\t\t\t90 Vac &nbsp;&nbsp;<\/p>\n<\/td>\n<td>\n<p>\n\t\t\t\t\t160 Vac<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\n\t\t\t\t\t230Vac<\/p>\n<\/td>\n<td>\n<p>\n\t\t\t\t\t190 Vac<\/p>\n<\/td>\n<td>\n<p>\n\t\t\t\t\t265 Vac<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n\t&nbsp;<\/p>\n<ul>\n<li>\n\t\tThe limit for the impedance alarm is configurable by the user and can vary between 0 and 100 &Omega;.<\/li>\n<li>\n\t\tThe default value for this limit is 25 &Omega;.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"How_does_the_AT-3503_Power_Supply_Tester_work\"><\/span>\n\t<strong>How does the AT-3503 Power Supply Tester work?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\n\tWhen the Power Supply Tester determines the type of network and is configured it enters the normal operating mode, where the voltage values of the lines, impedance and frequency are displayed on the main screen.<\/p>\n<p>\n\tOnce an event occurs, the equipment activates the corresponding relay(s) and alternatively displays the main screen and the display(s) of the events. When the anomaly ceases, the computer keeps the event logged in memory, disables the output and returns to the main screen.<\/p>\n<p>\n\tThe <a href=\"https:\/\/at3w.com\/upload\/pdf_producto\/AT-3503_I.PDF\" target=\"_blank\" rel=\"noopener noreferrer\">AT-3503 Power Supply Tester <\/a>of Aplicaciones Tecnol&oacute;gicas allows you to test the dry contact relays of the equipment to verify they work properly.<\/p>\n<p>\n\tIt allows three different types of tests:<\/p>\n<ul>\n<li>\n\t\tTest 1: activates the output voltage and the output impedance for 15 seconds.<\/li>\n<li>\n\t\tTest 2: activates the output voltage for 15 seconds. Output impedance remains off.<\/li>\n<li>\n\t\tTest 3: activates output impedance for 15 seconds. Output voltage remains off.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"How_many_records_can_you_save_in_the_memory\"><\/span>\n\t<strong>How many records can you save in the memory?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\n\tThe equipment registers the events so that the user can review them. The Power Supply Tester memory records a total of 50 voltage events and 50 impedance events. You can check the memory status of each event on the main screen.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Technical_Characteristics_of_the_Power_Supply_Tester_AT-3503\"><\/span>\n\t<strong>Technical Characteristics of the Power Supply Tester AT-3503<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>\n\t\tNominal voltage (L-N) \/ (L-L): 120 Vac \/ 230 Vac [ 230 Vac \/ 400 Vac.<\/li>\n<li>\n\t\tMaximum continuous operating voltage: 400 Vac.<\/li>\n<li>\n\t\tNominal frequency: 50\/60 Hz.<\/li>\n<li>\n\t\tImpedance reading from 1&Omega; to &gt;100&Omega;.<\/li>\n<li>\n\t\tVoltage variation alert output 120 Vac: programmable, 90 Vac Undervoltage and 150 Vac Overvoltage by standards.<\/li>\n<li>\n\t\tVoltage variation alert output 230 Vac: programmable, 190 Vac Undervoltage and 265 Vac Overvoltage by regulation.<\/li>\n<li>\n\t\tImpedance variation alert output: programmable, default 25&Omega;.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"What_type_of_installation_does_it_require\"><\/span>\n\t<strong>What type of installation does it require?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\n\tThe device must be installed in parallel with the low voltage line, downstream of the power control circuit breaker, with connections to phase, neutral and earth.&nbsp;Installation and handling should be carried out without power in the line.<\/p>\n<p>\n\tIn addition, it is recommended to always install the equipment together with the appropriate temporary and transient overvoltage protectors.<\/p>\n<p>\n\tFor more information about the Power Supply Tester AT-3503 from Aplicaciones Tecnol&oacute;gicas S.A, please contact our expert technicians <a href=\"https:\/\/lightningprotection-at3w.com\" target=\"_blank\" rel=\"noopener noreferrer\"><u>here.<\/u><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\n\tThe new AT-3503 Power Supply Tester of <a href=\"https:\/\/lightningprotection-at3w.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">Aplicaciones Tecnol&oacute;gicas<\/a> is responsible for monitoring and detecting dangerous voltages, network frequency variations as well as increases in the resistance of the earth loop of an installation. The line tester detects any network anomaly by acting through its dry contact relays.<\/p>\n","protected":false},"author":11,"featured_media":50165,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[5549,5574],"tags":[],"class_list":["post-50164","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-smart-lightning-en","category-surge-protection"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503<\/title>\n<meta name=\"description\" content=\"The new AT-3503 Power Supply Tester of Aplicaciones Tecnol&oacute;gicas is responsible for monitoring and detecting dangerous voltages, network frequency variations as well as increases in the resistance of the earth loop of an installation. The line tester detects any network anomaly by acting through its dry contact relays.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503\" \/>\n<meta property=\"og:description\" content=\"The new AT-3503 Power Supply Tester of Aplicaciones Tecnol&oacute;gicas is responsible for monitoring and detecting dangerous voltages, network frequency variations as well as increases in the resistance of the earth loop of an installation. The line tester detects any network anomaly by acting through its dry contact relays.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/\" \/>\n<meta property=\"og:site_name\" content=\"Aplicaciones Tecnol\u00f3gicas\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/APLICACIONES.TECNOLOGICAS\/\" \/>\n<meta property=\"article:published_time\" content=\"2019-09-25T22:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1\" \/>\n\t<meta property=\"og:image:height\" content=\"1\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"I\u00f1aki Fern\u00e1ndez\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"I\u00f1aki Fern\u00e1ndez\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/\"},\"author\":{\"name\":\"I\u00f1aki Fern\u00e1ndez\",\"@id\":\"https:\/\/at3w.com\/en\/#\/schema\/person\/6be7c94c178b1848a14e3573ad187f21\"},\"headline\":\"Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503\",\"datePublished\":\"2019-09-25T22:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/\"},\"wordCount\":640,\"publisher\":{\"@id\":\"https:\/\/at3w.com\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg\",\"articleSection\":[\"SMART LIGHTNING\",\"Surge Protection\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/\",\"url\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/\",\"name\":\"Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503\",\"isPartOf\":{\"@id\":\"https:\/\/at3w.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg\",\"datePublished\":\"2019-09-25T22:00:00+00:00\",\"description\":\"The new AT-3503 Power Supply Tester of Aplicaciones Tecnol&oacute;gicas is responsible for monitoring and detecting dangerous voltages, network frequency variations as well as increases in the resistance of the earth loop of an installation. The line tester detects any network anomaly by acting through its dry contact relays.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#primaryimage\",\"url\":\"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg\",\"contentUrl\":\"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg\"},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/at3w.com\/en\/#website\",\"url\":\"https:\/\/at3w.com\/en\/\",\"name\":\"Aplicaciones Tecnol\u00f3gicas\",\"description\":\"Smart Earthing Smart Lightning\",\"publisher\":{\"@id\":\"https:\/\/at3w.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/at3w.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/at3w.com\/en\/#organization\",\"name\":\"Aplicaciones Tecnol\u00f3gicas\",\"url\":\"https:\/\/at3w.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/at3w.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/at3w.com\/wp-content\/uploads\/2019\/02\/LOGO-HOME-APLICACIONES-TECNOLOGICAS.svg\",\"contentUrl\":\"https:\/\/at3w.com\/wp-content\/uploads\/2019\/02\/LOGO-HOME-APLICACIONES-TECNOLOGICAS.svg\",\"width\":114,\"height\":104,\"caption\":\"Aplicaciones Tecnol\u00f3gicas\"},\"image\":{\"@id\":\"https:\/\/at3w.com\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/APLICACIONES.TECNOLOGICAS\/\",\"https:\/\/www.linkedin.com\/company\/aplicaciones-tecnologicas\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/at3w.com\/en\/#\/schema\/person\/6be7c94c178b1848a14e3573ad187f21\",\"name\":\"I\u00f1aki Fern\u00e1ndez\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/at3w.com\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d7d93a125afe2c52583a19f93806f9302eca1ef6cfca882769cc289293498b93?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d7d93a125afe2c52583a19f93806f9302eca1ef6cfca882769cc289293498b93?s=96&d=mm&r=g\",\"caption\":\"I\u00f1aki Fern\u00e1ndez\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503","description":"The new AT-3503 Power Supply Tester of Aplicaciones Tecnol&oacute;gicas is responsible for monitoring and detecting dangerous voltages, network frequency variations as well as increases in the resistance of the earth loop of an installation. The line tester detects any network anomaly by acting through its dry contact relays.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/","og_locale":"en_US","og_type":"article","og_title":"Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503","og_description":"The new AT-3503 Power Supply Tester of Aplicaciones Tecnol&oacute;gicas is responsible for monitoring and detecting dangerous voltages, network frequency variations as well as increases in the resistance of the earth loop of an installation. The line tester detects any network anomaly by acting through its dry contact relays.","og_url":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/","og_site_name":"Aplicaciones Tecnol\u00f3gicas","article_publisher":"https:\/\/www.facebook.com\/APLICACIONES.TECNOLOGICAS\/","article_published_time":"2019-09-25T22:00:00+00:00","og_image":[{"url":"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg","width":1,"height":1,"type":"image\/jpeg"}],"author":"I\u00f1aki Fern\u00e1ndez","twitter_card":"summary_large_image","twitter_misc":{"Written by":"I\u00f1aki Fern\u00e1ndez","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#article","isPartOf":{"@id":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/"},"author":{"name":"I\u00f1aki Fern\u00e1ndez","@id":"https:\/\/at3w.com\/en\/#\/schema\/person\/6be7c94c178b1848a14e3573ad187f21"},"headline":"Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503","datePublished":"2019-09-25T22:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/"},"wordCount":640,"publisher":{"@id":"https:\/\/at3w.com\/en\/#organization"},"image":{"@id":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#primaryimage"},"thumbnailUrl":"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg","articleSection":["SMART LIGHTNING","Surge Protection"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/","url":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/","name":"Aplicaciones Tecnol\u00f3gicas launches a new product, the Power Supply Tester AT-3503","isPartOf":{"@id":"https:\/\/at3w.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#primaryimage"},"image":{"@id":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#primaryimage"},"thumbnailUrl":"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg","datePublished":"2019-09-25T22:00:00+00:00","description":"The new AT-3503 Power Supply Tester of Aplicaciones Tecnol&oacute;gicas is responsible for monitoring and detecting dangerous voltages, network frequency variations as well as increases in the resistance of the earth loop of an installation. The line tester detects any network anomaly by acting through its dry contact relays.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/at3w.com\/en\/blog\/aplicaciones-tecnologicas-launches-a-new-product-the-power-supply-tester-at-3503\/#primaryimage","url":"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg","contentUrl":"https:\/\/at3w.com\/wp-content\/uploads\/power_supply_tester_at-3503_by_aplicaciones_tecnologicas_833x512_en-2.jpg"},{"@type":"WebSite","@id":"https:\/\/at3w.com\/en\/#website","url":"https:\/\/at3w.com\/en\/","name":"Aplicaciones Tecnol\u00f3gicas","description":"Smart Earthing Smart Lightning","publisher":{"@id":"https:\/\/at3w.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/at3w.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/at3w.com\/en\/#organization","name":"Aplicaciones Tecnol\u00f3gicas","url":"https:\/\/at3w.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/at3w.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/at3w.com\/wp-content\/uploads\/2019\/02\/LOGO-HOME-APLICACIONES-TECNOLOGICAS.svg","contentUrl":"https:\/\/at3w.com\/wp-content\/uploads\/2019\/02\/LOGO-HOME-APLICACIONES-TECNOLOGICAS.svg","width":114,"height":104,"caption":"Aplicaciones Tecnol\u00f3gicas"},"image":{"@id":"https:\/\/at3w.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/APLICACIONES.TECNOLOGICAS\/","https:\/\/www.linkedin.com\/company\/aplicaciones-tecnologicas\/"]},{"@type":"Person","@id":"https:\/\/at3w.com\/en\/#\/schema\/person\/6be7c94c178b1848a14e3573ad187f21","name":"I\u00f1aki Fern\u00e1ndez","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/at3w.com\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d7d93a125afe2c52583a19f93806f9302eca1ef6cfca882769cc289293498b93?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7d93a125afe2c52583a19f93806f9302eca1ef6cfca882769cc289293498b93?s=96&d=mm&r=g","caption":"I\u00f1aki Fern\u00e1ndez"}}]}},"_links":{"self":[{"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/posts\/50164","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/comments?post=50164"}],"version-history":[{"count":0,"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/posts\/50164\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/media\/50165"}],"wp:attachment":[{"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/media?parent=50164"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/categories?post=50164"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/at3w.com\/en\/wp-json\/wp\/v2\/tags?post=50164"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}