Transient Overvoltages - Aplicaciones Tecnológicas

Protection against transient overvoltages

Sobretensiones transitorias, Transient overvoltages, Surtensions transitoires, Sobretensões transitórias
null

Transient
Overvoltages

The internal protection against lightning safeguards electrical and electronic equipment against transient overvoltages caused by the electromagnetic impulses of a lightning bolt.

Keep equipment connected go power or data lines safe from indirect lightning discharges, switching processes or failures.

  1. Aplicaciones Tecnológicas
  2. /
  3. Smart Lightning
  4. /
  5. Protection against transient overvoltages

Transient Overvoltages
and
protective devices

Transient overvoltages are an increase of voltage on the electrical network, measured between two conductors. It may be due to atmospheric electric discharges (lightning), to switching or faulty processes (grounding or short circuit). The most destructive are those due to lightning.

Protection devices must respond instantly, safeguarding the equipment connected to the power supply lines and the data lines. The application standards in this field are IEC 61643-11 and IEC 61643-21.

How do overvoltages
enter the equipment?

Power supply, telephone, TV or data lines often cover long distances, far from any protected areas, and are connected to very sensitive equipment. This condition makes the lines especially receptive to overvoltages, which will then be transmitted by conduction to the connected equipment.

Care must be taken with overhead lines that connect sensitive equipment even in protected environments, as it is likely that dangerous voltages may be induced. It is also important to take into account that lightning and power switching generate high magnitude electromagnetic fields, thus inducing currents in the conductors placed inside the field.

Finally, lightning effects can enter through the earthing system, changing the voltage reference of all the equipment connected to it or to the power supply line itself.

In addition, when there are several buildings in the same area, the risk can increase due to the higher number of possible interconnections.

null

Our Surge
Protective
Devices range

Selection Guide

This overvoltage guide is published to achieve a correct protection of any installation by choosing, just with a few questions, the proper Surge Protective Device model.

  • Is there any external lightning protection?

  • Overhead or buried power supply line

  • Domestic or industrial environment

  • Main or secondary board

  • Single or three-phase line

null
null

Power supply
protection

Therefore, proper overvoltage protection requires staggered and coordinated protectors with several protection stages acting sequentially so that they are able to, on the one hand, withstand all the lightning current and, on the other, leave a residual voltage which is harmless for the existing equipment or that which will later be installed.

Type 1

Type 1 protectors against transient overvoltages should be tested with 10/350 µs lightning impulse wave, simulating the effects of direct lightning discharges.

Type 2

Type 2 protectors against transient overvoltages should be tested with 8/20 µs current impulse wave, simulating lightning secondary effects.

Type 3

Type 3 protectors against transient overvoltages should be tested with a combination impulse wave, simulating very attenuated overvoltages.

Type 1+2

Type 1+2 protectors against transient overvoltages should be tested with 10/350 µs lightning impulse wave and 8/20 µs wave, combining the capacity to absorb lightning current with low residual voltage.

Type 2+3

Type 2+3 protectors against transient overvoltages should be tested with 8/20 µs current impulse wave and a combination impulse wave, leaving low residual voltages.

Power supply protection for
special equipment

The different power supply protector series focus on AC power supply systems for different voltages. However, there is a lot of equipment which is supplied by special generators, such as batteries or solar cells with different types of voltages (continuous, pulses etc.) and a wide range of different characteristics regarding current, frequency, number of wires etc.

Very often this equipment is located in areas which are difficult to access, in usual storm areas and carrying out very important functions such as telecommunications, forest vigilance, environmental control etc. The protection of this type of equipment not only prevents destruction but also it being moved for repair, as well as interruption of the services they carry out.

null
Power supply protection for special equipment

Protectors against transient overvoltages for special equipment with DC voltages.

null

Data and telecommunication
line protection

Surges often enter structures via telephone and data lines, thus affecting the equipment. Just like power supply lines, they can cover large distances and connect very sensitive electronic equipment. Besides, telephone and data lines usually drive very low currents and reach the most fragile components.

Data communication lines directly connect to integrated circuits, other electronic components through the printed board thin tracks. Surges can cause severe damage in these tracks and components, deteriorating or destroying them and also affecting the data they store. Telephone lines connect not only phone terminals but also more important and sensitive equipment, such as faxes and modems, inside and outside computers.

Furthermore, one of the consequences of the global use of the internet is that many machines (PLCs, electrical household appliances etc.) activate through the data line (home automation). This gives rise to the appearance of a new trend which consists of designing all kinds of devices for controlling electronic equipment from remote distances. This process often means the multiplication of cross-connections and wiring between devices that are placed in separate buildings or with different earthing systems. The risk of overvoltages damaging the equipment then increases considerably, causing great financial loss not only due to the equipment damage but also the delay or cancellation of the processes and the services they should provide.

Telephone lines

Protectors against transient overvoltages for analogic, ADSL and ISDN telephone lines with screw, RJ, R&M and Krone type connectors.

Computer networks

Protection against transient overvoltages for computer networks with category 5e, 6 or POE wiring.

Data lines

Protection against transient overvoltages for analogical and digital data lines (computers, PLCs, load cells etc.).

Coaxial cables

Protection against transient overvoltages for coaxial cables with TV, F, BNC, N UHF and 7/16 connectors.

Related news

Transient overvoltages: what are they, what damage can they cause and types of suitable protectors

How does a surge protection device work?

Transient overvoltages: how to protect LED lighting

Upcoming free online webinars for professionals: october 2022

Contact

TRANSIENT OVERVOLTAGES



    I would like to speak with a expert.

    Receive the lastest news and product information from Aplicaciones Tecnológicas.


    START TYPING AND PRESS ENTER TO SEARCH